Determination of quinidine by high-performance liquid chromatography.
نویسندگان
چکیده
منابع مشابه
Determination of quinidine by high-performance liquid chromatography.
Quinidine in serum was measured at 330 nm, after protein precipitation, with an alkyl phenyl reversed-phase chromatographic column by peak-height determination (external standards.) Sensitivity was 0.3 mg/liter, with linear response to at least 10 mg/liter serum. Interassay precision, measured on 20 consecutive days, gave a CV of 8.2% at 2 mg/liter of serum and 5.1% at 5 mg/liter. Quinine and p...
متن کاملHigh-Performance Liquid Chromatography Determination of Methotrexate in Plasma
This article describes a simple and fast high-performance liquid chromatography method for the determination of methotrexate (MTX) in plasma. Samples were collocted from children receiving high-dose MTX at shafa Hospital (Ahvaz University of Medical sciences, Ahvaz, iran) at various times after the end of eachinfusion. Plasma was deproteinized with trichloroacetic acid and the supernatant was i...
متن کاملHigh-Performance Liquid Chromatography Determination of Methotrexate in Plasma
This article describes a simple and fast high-performance liquid chromatography method for the determination of methotrexate (MTX) in plasma. Samples were collocted from children receiving high-dose MTX at shafa Hospital (Ahvaz University of Medical sciences, Ahvaz, iran) at various times after the end of eachinfusion. Plasma was deproteinized with trichloroacetic acid and the supernatant was i...
متن کاملHigh Performance Liquid Chromatography Determination of Sertraline in Human
An accurate and sensitive reversed-phase high-performance liquid chromatograph-ic method for determination of sertraline in human serum is described using 4-chloro-7-nitrobenzofurazan as pre-column derivatization agent. The drug and an internal standard (azithrimycin) were extracted from serum using a mixture of diethyl ether-chloroform and subjected to the pre-column derivatization with...
متن کاملdetermination of gamma - aminobutyric acid by high-performance liquid chromatography
gamma-aminobutyric acid is the main inhibitory amino acid neurotransmitter in several areas of the brain. measurement of gamma-aminobutyric acid in the brain will help elucidate its metabolic rote and diagnostic value. the liquid chromatography (lc) system consisted of a delivery pump. male rats (150-250g) were used in this study. the brain was rapidly removed from decapitated animals. trie chr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Clinical Chemistry
سال: 1978
ISSN: 0009-9147,1530-8561
DOI: 10.1093/clinchem/24.2.299