Determination of SDS Using Fluorescent <i>γ</i>-Cyclodextrin Based on TICT in Aqueous Solution
نویسندگان
چکیده
منابع مشابه
Determination of SDS using fluorescent γ-cyclodextrin based on TICT in aqueous solution.
Fluorescent γ-cyclodextrin derivatives, modified using N-phenyl-x-anthracenecarboxamido (ACs; x = 9, 1), were synthesized and investigated using fluorescence and UV-vis spectroscopy. Fluorescence enhancements of ACs were observed up to 12-fold by the addition of sodium dodecyl sulfate (SDS) below the critical micellar concentration (CMC). In the presence of a nonionic surfactant, such as Trit...
متن کاملthe effect of aqueous extract of garlic on formalin-induced pain in male rats
چکیده اثر عصاره آبی سیر بر درد ناشی از آزمون فرمالین در موش صحرایی نر به کوشش نرگس اسکندری روزبهانی زمینه و هدف: گیاه سیر از خانواده لیلیاسه و گونهallium sativum بومی آسیای میانه بوده و از دوران ،باستان تاکنون به خواص درمانی متفاوت آن مثل: کاهندگی قندخون، کلسترول خون، فشار خون، اثرات مفیدآن بر دستگاه قلبی عروقی و بیماریهای انعقادی خون، اثرات آنتی اکسیداتیو، درمان بیماریهای تنفسی وگوارشی، ا...
15 صفحه اولRemoval of Manganese from an Aqueous Solution Using Micellar-Enhanced Ultrafiltration (MEUF) with SDS Surfactants
In the present study, micellar-enhanced ultrafiltration (MEUF) was used to remove manganese (Mn) (II) from synthetic wastewater. The effects of different operational conditions on the filtration performance of MEUF or the membrane were studied. It was found that the transmembrane pressure has a major influence on the permeate flux and an insignificant effect on the rejection coefficient. The pe...
متن کاملA polythiophene-derived ratiometric fluorescent sensor for highly sensitive determination of carbenicillin in aqueous solution.
A new ratiometric fluorescent sensor based on a quaternized quinine substituted 3-phenylpolythiophene derivative (PTQ1) was designed and developed for facile and reliable detection of carbenicillin with high sensitivity and selectivity.
متن کاملA ratiometric fluorescent probe for hydrophobic proteins in aqueous solution based on aggregation-induced emission.
A novel fluorescent probe 1 is reported here with ratiometric response to hydrophobic proteins (casein) or proteins with hydrophobic pockets (BSA, HSA) through hydrophobic interaction. Probe 1 underwent deprotonation in aqueous solution at pH 7.4 and emitted blue fluorescence at 436 nm. Upon the addition of BSA, HSA or casein, the aggregation-induced emission fluorescence of 1 at 518 nm was tur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Analytical Sciences
سال: 2012
ISSN: 0910-6340,1348-2246
DOI: 10.2116/analsci.28.973