DETERMINATION OF URINARY GLYCOLATE BY ION CHROMATOGRAPHY
نویسندگان
چکیده
منابع مشابه
Rapid determination of urinary total porphyrins by ion exchange chromatography.
Total urinary porphyrins were eluted from a commercially available anion exchange Chromatographie column with hydrochloric acid and determined spectrophotometrically. For 1 ml samples the optimum concentration range for measurement was found to lie between 0.1 and 1.5 mg of total porphyrin/1 urine. Assay of a single sample takes 12 min. The specificity (measurement at three wave lengths), sensi...
متن کاملDetermination of urinary oxalate by ion chromatography: some modifications.
Ion chromatography was used to determine urinary oxalate concentration. The minimal detectable limit in a standard solution was 0.02 microgram/ml, and the regression line for the standard curve from 0.5 to 10 micrograms/ml had a significant correlation coefficient (p less than 0.01), but it was difficult to obtain reproducible results with ion chromatography. There were two obstacles: Urine was...
متن کاملTitle Determination of urinary oxalate by ion chromatography: some modifications
Ion chromatography was used to determine urinary oxalate concentration. The minimal detectable limit in a standard solution was 0.02 flg/ml, and the regression line for the standard curve from 0.5 to 10 flg/ml had a significant correlation coefficient (p<O. 01), but it was difficult to obtain reproducible results with ion chromatography. There were two obstacles: Urine was always oversaturated ...
متن کاملThiocyanate determination by ion pair chromatography
Department of Analytical and Environmental Chemistry, Vilnius University, Naugarduko 24, LT-03225 Vilnius, Lithuania A simple and rapid ion pair chromatographic method has been developed for the determination of thiocyanate. Separation was carried out on a 25 cm × 4.6 mm Ascentis C18 column (5 μm particle size) with a mobile phase containing 2 mmol/l tetrabutylammonium (TBA)-phosphate (pH 6.5) ...
متن کاملDetermination of urinary oxalate by reversed-phase ion-pair "high-performance" liquid chromatography.
In this liquid-chromatographic method for determination of urinary oxalate, interfering compounds in the urinary samples were eliminated before chromatography by passage through a preparative C18 mini-column (Sep-pak cartridge, Waters Associates). In the reversed-phase system tetrabutyl ammonium was included as a counter ion to enhance the retention of oxalate. The pH of the mobile phase was ke...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Japanese Journal of Urology
سال: 1997
ISSN: 0021-5287,1884-7110
DOI: 10.5980/jpnjurol1989.88.984