Developing a grid-connected DFIG strategy for the integration of wind power with harmonic current mitigation
نویسندگان
چکیده
منابع مشابه
Variable speed DFIG wind energy system for power generation and harmonic current mitigation
This paper presents a novel approach for simultaneous power generation and harmonic current mitigation using variable speed WECS with DFIG. A new control strategy is proposed to upgrade the DFIG control to achieve simultaneously a green active and reactive power source with active filtering capability. To ensure high filtering performance, we studied an improved harmonic isolator in the timedom...
متن کاملDfig-based Wind Power Conversion System Connected to Grid
This paper presents the complete modeling and real-time simulation of wind turbine driven doubly-fed induction generator (DFIG) which feeds ac power to the utility grid. For that, two pulse width modulated voltage source converters are connected back to back between the rotor terminals and utility grid via common dc link. It is found that there are so many limitations in the conventional contro...
متن کاملA Novel Control Strategy for a Single-phase Grid-connected Power Injection System
In this paper, a novel and simple control strategy, based on state feedback method is suggested to control the power injection system (PIS). The considered PIS is composed of, a DC voltage source, a voltage source inverter (VSI) and a L-C-L filter. The DC source includes the battery source with boosted voltage. The battery can be charged with photovoltaic cells. Since, the grid voltage acts as ...
متن کاملPower Quality Enhancement in Grid Connected Wind Power System Based on Dfig Using Fuzzy Controlled Upqc
The renewable energy resources rule the world of power generation. Now-a-days wind farms are encouraged for up gradation of energy production, as the wind power is dirt free, readily available renewable alternative. The integration of wind farms with power grid leads to Power Quality (PQ) issues such as voltage sag, swell, flicker, harmonics etc. Most of the industrial and commercial loads are ...
متن کاملWind farm node connected DFIG/back-to-back converter coupling transient model for grid integration studies
This paper presents the explicit electromagnetic transient model of a Doubly Fed Induction Generator (DFIG), that includes its coupling with the back-to-back converter, when the generator/converter set is connected to the wind farm’s Thevenin equivalent, as seen from DFIG’s terminals. Besides that, DFIG’s grid side converter control system is defined in detail, so that expressions for the direc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Electrical and Computer Engineering (IJECE)
سال: 2019
ISSN: 2722-2578,2088-8708
DOI: 10.11591/ijece.v9i5.pp3905-3915