Development and Evaluation of a Simple Assay for Marburg Virus Detection Using a Reverse Transcription-Loop-Mediated Isothermal Amplification Method
نویسندگان
چکیده
منابع مشابه
A reverse transcriptase-loop mediated isothermal amplification assay (RT-LAMP) for rapid detection of bovine viral diarrhea virus 1 and 2
Bovine viral diarrhea virus (BVDV) is a pathogen that infects cattle, and is globally important. It causes substantial financial losses to the livestock industry. In the current study, a one-step reverse transcriptase-loop-mediated isothermal amplification (RT-LAMP) assay was set up for rapid and efficient detection of BVDV. For this purpose, four primers were designed to recognize six distinct...
متن کاملReverse transcription-loop-mediated isothermal amplification assay for rapid detection of hepatitis E virus.
The one-step single-tube betaine-free reverse transcription (RT)-loop-mediated isothermal amplification assay was developed for rapid diagnosis of hepatitis E virus. This assay amplified the target gene in less than 45 min (even as short as 20 min) under isothermal conditions at 63 degrees C, and the sensitivity of this assay was 100-fold greater than that of RT-PCR. This assay demonstrated a d...
متن کاملDevelopment of a Rapid Detection Method for Potato virus X by Reverse Transcription Loop-Mediated Isothermal Amplification
The primary step for efficient control of viral diseases is the development of simple, rapid, and sensitive virus detection. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) has been used to detect viral RNA molecules because of its simplicity and high sensitivity for a number of viruses. RT-LAMP for the detection of Potato virus X (PVX) was developed and compared with con...
متن کاملDevelopment of a Reverse Transcription Loop-Mediated Isothermal Amplification Method for the Rapid Detection of Subtype H7N9 Avian Influenza Virus
A novel influenza A (H7N9) virus has emerged in China. To rapidly detect this virus from clinical samples, we developed a reverse transcription loop-mediated isothermal amplification (RT-LAMP) method for the detection of the H7N9 virus. The minimum detection limit of the RT-LAMP assay was 0.01 PFU H7N9 virus, making this method 100-fold more sensitive to the detection of the H7N9 virus than con...
متن کاملDevelopment and evaluation of reverse transcription-loop-mediated isothermal amplification assay for rapid detection of enterovirus 71
Human enterovirus 71 (EV71) is the major etiological agent of hand, foot, and mouth disease (HFMD), which is a common infectious disease in young children and infants. EV71 can cause various clinical manifestations and has been associated with severe neurological complications; it has resulted in fatalities during recent outbreaks in Asian-Pacific regions since 1997. The early and rapid detecti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Clinical Microbiology
سال: 2010
ISSN: 0095-1137,1098-660X
DOI: 10.1128/jcm.01224-09