Development of a novel segmented mesh MicroMegas detector for neutron beam profiling

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation of a Neutron Detector for Real Time Imaging Applications

Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...

متن کامل

Micromegas Detector for the Cast Experiment

A low background Micromegas detector has been operating on the CAST experiment at CERN for the search of solar axions during the first phase of the experiment (2002-2004). The detector operated efficiently and achieved a very low level of background rejection (5 × 10 −5 counts keV −1 cm −2 s −1) thanks to its good spatial and energy resolution as well as the low radioactivity materials used in ...

متن کامل

A Novel Neutron Dosimeter

Background: Neutron contamination in our environment can cause harmful biological effects on human body. Therefore, many efforts have been made to construct a neutron dosimeter to estimate the received dose. Objective: To design a simple neutron dosimeter. Methods: The primary dosimeter had 3He as a spherical thermal neutron detector encircled by paraffin 10 cm in radius. Then, the paraffin sph...

متن کامل

The Micromegas detector of the CAST experiment

A low background Micromegas detector has been operating in the CAST experiment at CERN for the search of solar axions during the first phase of the experiment (2002-2004). The detector, made out of low radioactivity materials, operated efficiently and achieved a very low level of background rejection (5 × 10 −5 counts keV −1 cm −2 s −1) without shielding.

متن کامل

Development of a Position Sensitive Neutron Detector with High Efficiency and Energy Resolution for Use at High-Flux Beam Sources

We are developing a high-efficiency neutron detector with 1 cm position resolution and coarse energy resolution for use at high-flux neutron source facilities currently proposed or under construction. The detector concept integrates a segmented (3)He ionization chamber with the position sensitive, charged particle collection methods of a MicroMegas detector. Neutron absorption on the helium pro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

سال: 2018

ISSN: 0168-9002

DOI: 10.1016/j.nima.2018.06.019