Development of a time-resolved mirrorless scintillation detector
نویسندگان
چکیده
منابع مشابه
Development of a fast pixel array detector for use in microsecond time- resolved x-ray diffraction
A large-area pixel x-ray detector is being developed to collect eight successive frames of wide dynamic range two-dimensional images at 200kHz rates. Such a detector, in conjunction with a synchrotron radiation x-ray source, will enable time-resolved x-ray studies of proteins and other materials on time scales which have previously been inaccessible. The detector will consist of an array of ful...
متن کاملDevelopment of a two-dimensional virtual-pixel X-ray imaging detector for time-resolved structure research.
An interpolating two-dimensional X-ray imaging detector based on a single-photon counter with gas amplification by GEM (gas electron multiplier) structures is presented. The detector system can be used for time-resolved structure research down to the micro s time domain. The prototype detector has been tested at the SAXS (small-angle X-ray scattering) beamline at ELETTRA synchrotron light sourc...
متن کاملDevelopment Of A Pixel Array Detector For Time Resolved X-ray Imaging
We are developing an integrating Pixel Array Detector (PAD) for microsecond timeresolved x-ray diffraction. The current detector prototype has a format of 92x100 pixels, each 150μm square, and covers an active area of 15x13.8 mm. The detector was tested at the CHESS D1 beamline and imaging capabilities within the microsecond time resolution regime were successfully demonstrated. This prototype ...
متن کاملSimulation of a Neutron Detector for Real Time Imaging Applications
Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...
متن کاملSU-E-T-168: Development of a Liquid Scintillation Detector for External Beam Dosimetry.
PURPOSE The goal of this research was to design a liquid scintillation dosimeter that could be used forrelative dosimetry of linear accelerator fields. The project emphasized minimization of cost and ease of use. METHODS The scintillator that was used in this research was BETAMAX- ES scintillation cocktail from MPBiomedical. This particular scintillator was selected due to its relatively high...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: PLOS ONE
سال: 2021
ISSN: 1932-6203
DOI: 10.1371/journal.pone.0246742