Development of a water-mist cooling system: A 12,500 Kcal/h air-cooled chiller
نویسندگان
چکیده
منابع مشابه
Optimization of Water - Cooled Chiller – Cooling Tower Combinations
Water-cooled chiller systems have typically been designed around entering condenser water temperatures of 85°F with a Optimization of Water Cooled Chiller – Cooling Tower Combinations The warm water leaving the chilled water coils is pumped to the evaporator of the chiller, where the unwanted heat from the building is transferred by the latent heat of vaporization of the refrigerant. The compre...
متن کاملApplication of Water Mist Pre-cooling on the Air-cooled Chillers
The operation of air-cooled chillers accounts for significant energy consumption in local commercial buildings, and low operational efficiency especially under partial load conditions and poor control are part of reasons for such huge energy consumption. Chiller efficiency can be improved by enhancing heat transfer rate in condensers. This paper considers how the chiller performance can be impr...
متن کاملApplication of Air - Cooled Chiller for Comfort and Energy Saving
In this study, a frequency converter was used to carry out variable frequency control to the compressor with constant frequency of a small 3RT central air-conditioning air-cooled chiller, but the indoor blower and cooled water pump were still kept by constant frequency operation. It is to explore the energy-saving effect of chiller compressor and the cooling fan after being carried out the vari...
متن کاملEvaluation of Damage Problems in the Water Pump Components of an Air Compressor Cooling System: a Case Study
In this paper, the reasons of damage water pumps parts of the air compressor cooling system were studied. To reach this goal, the works like preparing metallographic samples, evaluation of structure, investigation of mechanical properties, the alloy parts detection and chemical analysis of deposit and corrosion products collected from the parts were performed. According to studies and results o...
متن کاملEvaluation of Damage Problems in the Water Pump Components of an Air Compressor Cooling System: a Case Study
In this paper, the reasons of damage water pumps parts of the air compressor cooling system were studied. To reach this goal, the works like preparing metallographic samples, evaluation of structure, investigation of mechanical properties, the alloy parts detection and chemical analysis of deposit and corrosion products collected from the parts were performed. According to studies and results o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energy Reports
سال: 2015
ISSN: 2352-4847
DOI: 10.1016/j.egyr.2015.04.002