DEVELOPMENT OF AMPEROMETRIC BIOSENSOR FOR GLUTAMATE DETERMINATION

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Different Functionalized CNTs for Development of Choline Amperometric Biosensor

Choline oxidase (ChOx) was chosen as a model enzyme for evaluating the performance of CNTs’ functional groups for development of enzyme electrodes. CNTs were functionalized with carboxylic acid, amine or amide groups. Carboxylic acid, amine and amide functionalized CNTs were obtained by acid treatment, ethylenediamine or tetraethylenepentamine chemically modification and ammonia plasma treatmen...

متن کامل

Modelling of Amperometric Biosensor Used for Synergistic Substrates Determination

In this paper the operation of an amperometric biosensor producing a chemically amplified signal is modelled numerically. The chemical amplification is achieved by using synergistic substrates. The model is based on non-stationary reaction-diffusion equations. The model involves three layers (compartments): a layer of enzyme solution entrapped on the electrode surface, a dialysis membrane cover...

متن کامل

Development of biosensor based on immobilized L-glutamate oxidase for determination of monosodium glutamate in food.

A monosodium glutamate (MSG) biosensor with immobilized L-glutamate oxidase (L-GLOD) has been developed and studied for analysis of MSG in sauces, soup etc. The immobilized enzymatic membrane was attached with oxygen electrode with a push cap system. The detection limit of the sensor was 1 mg/dl and the standard curve was found to be linear upto 20 mg/dl. Response time of the sensor was 2 min. ...

متن کامل

Development of a screen-printed amperometric biosensor for the determination of L-lactate dehydrogenase level.

We attempted to develop a screen-printed biosensor for the amperometric determination of L-lactate dehydrogenase (LDH) level on the basis of NAD(+)/NADH-dependent dehydrogenase reaction. The printing ink for the working electrode consisted of L-lactate, NAD(+), composite polymer of hydroxyethyl cellulose with ethylene glycol, 3,4-dihydroxybenzaldehyde (3,4-DHB) as an electron transferring media...

متن کامل

AMPEROMETRIC MICROBIOSENSOR FOR THE DETERMINATION OF CHOLINE

The construction and performance of an amperometric microbiosensor for the determination of choline chloride by immobilizing choline oxidase on a cellulose acetate membrane are described. The procedure of choline determination involved the electrochemical detection of enzymatically generated hydrogen peroxide. This microsensor has a linear response between 0.038-0.1 mM choline chloride. The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Sensor Electronics and Microsystem Technologies

سال: 2015

ISSN: 2415-3508,1815-7459

DOI: 10.18524/1815-7459.2015.1.104933