Development of a real-time stereo transmission electron microscope.
A new transmission electron microscope that allows for stereoscopic observations in real time at a video rate has been developed. In order to make stereo pairs at a high speed, illumination of a specimen from two directions instead of specimen tilting is adopted. Two electrostatic deflectors make it possible to alternate the illumination direction within a blank period of 1.2 ms between two adj...
متن کاملEffect of a physical phase plate on contrast transfer in an aberration-corrected transmission electron microscope.
In this theoretical study we analyze contrast transfer of weak-phase objects in a transmission electron microscope, which is equipped with an aberration corrector (C(s)-corrector) in the imaging lens system and a physical phase plate in the back focal plane of the objective lens. For a phase shift of pi/2 between scattered and unscattered electrons induced by a physical phase plate, the sine-ty...
متن کاملApproaches for ultrafast imaging of transient materials processes in the transmission electron microscope.
The growing field of ultrafast materials science, aimed at exploring short-lived transient processes in materials on the microsecond to femtosecond timescales, has spawned the development of time-resolved, in situ techniques in electron microscopy capable of capturing these events. This article gives a brief overview of two principal approaches that have emerged in the past decade: the strobosc...
متن کاملIsotope analysis in the transmission electron microscope
The Ångström-sized probe of the scanning transmission electron microscope can visualize and collect spectra from single atoms. This can unambiguously resolve the chemical structure of materials, but not their isotopic composition. Here we differentiate between two isotopes of the same element by quantifying how likely the energetic imaging electrons are to eject atoms. First, we measure the dis...
متن کاملChoice of operating voltage for a transmission electron microscope.
An accelerating voltage of 100-300kV remains a good choice for the majority of TEM or STEM specimens, avoiding the expense of high-voltage microscopy but providing the possibility of atomic resolution even in the absence of lens-aberration correction. For specimens thicker than a few tens of nm, the image intensity and scattering contrast are likely to be higher than at lower voltage, as is the...