Study of the performance of a solar adsorption cooling system
This article presents a transient model of a solar adsorption cooling system. A computer program has been developed to simulate the operation of a two bed silica gel- water adsorption cooling system as well as flat plate collectors and the hot water storage tank. This program is then utilized to simulate the performance of a sample solar adsorption cooling system used for cooling a set of r...
متن کاملOptimization of Solar Absorption Cooling System Considering Hourly Analysis
Thermal modelling and optimal design of a solar absorption cooling system are presented, and hourly analysis is performed over the period of a year. Three design parameters are considered, then the Real Parameter Genetic Algorithm (RPGA) is applied to obtain the minimum total annual cost. The optimization results show that the solar cooling optimum configuration needs 1630 square meter collecto...
متن کاملstudy of the performance of a solar adsorption cooling system
this article presents a transient model of a solar adsorption cooling system. a computer program has been developed to simulate the operation of a two bed silica gel- water adsorption cooling system as well as flat plate collectors and the hot water storage tank. this program is then utilized to simulate the performance of a sample solar adsorption cooling system used for cooling a set of rooms...
متن کاملPlanar micro-optic solar concentrator.
We present a new approach to solar concentration where sunlight collected by each lens in a two-dimensional lens array is coupled into a shared, planar waveguide using localized features placed at each lens focus. This geometry yields a thin, flat profile for moderate concentration systems which may be fabricated by low-cost roll manufacture. We provide analyses of tradeoffs and show optimized ...
متن کاملReliability of III-V concentrator solar cells
III-V concentrator solar cells are starting to be commercialized. However, no complete studies about their reliability have been carried out. A review about both the accelerated ageing tests and real time tests developed till now is presented. A proposal about the required tests is also done. In this stage, the tests show that III-V concentrator cells are robust devices with MTTFs well over the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Korea Academia-Industrial cooperation Society
سال: 2014
ISSN: 1975-4701
DOI: 10.5762/kais.2014.15.7.4463