Diagnostic accuracy of sensitive or high-sensitive troponin on presentation for myocardial infarction: a meta-analysis and systematic review
نویسندگان
چکیده
منابع مشابه
Diagnostic accuracy of sensitive or high-sensitive troponin on presentation for myocardial infarction: a meta-analysis and systematic review
BACKGROUND Recently, high-sensitive troponin (hsTrop) assays consistent with professional societies' recommendations became available. We aimed to summarize the evidence on the diagnostic accuracy of hsTrop on presentation. METHODS We searched electronic databases for studies evaluating the diagnostic accuracy of hsTrop in suspected acute coronary syndrome (ACS) patients. Random effect meta-a...
متن کاملDiagnostic accuracy of single baseline measurement of Elecsys Troponin T high-sensitive assay for diagnosis of acute myocardial infarction in emergency department: systematic review and meta-analysis
OBJECTIVE To obtain summary estimates of the accuracy of a single baseline measurement of the Elecsys Troponin T high-sensitive assay (Roche Diagnostics) for the diagnosis of acute myocardial infarction in patients presenting to the emergency department. DESIGN Systematic review and meta-analysis of diagnostic test accuracy studies. DATA SOURCES Medline, Embase, and other relevant electroni...
متن کاملfabrication of new ion sensitive field effect transistors (isfet) based on modification of junction-fet for analysis of hydronium, potassium and hydrazinium ions
a novel and ultra low cost isfet electrode and measurement system was designed for isfet application and detection of hydronium, hydrazinium and potassium ions. also, a measuring setup containing appropriate circuits, suitable analyzer (advantech board), de noise reduction elements, cooling system and pc was used for controlling the isfet electrode and various characteristic measurements. the t...
Rapid detection of myocardial infarction with a sensitive troponin test.
Rapid identification and treatment of patients with a myocardial infarction (MI) is mandatory. We studied the diagnostic capacities of a sensitive troponin assay for detection of MI in emergency department patients within 2 hours after arrival. The study included 157 patients suspected of having non-ST-elevation acute coronary syndrome. Blood was drawn on arrival (T0) and 2 (T2), 6, and 12 hour...
متن کاملSensitive Troponin Assay and the Classification of Myocardial Infarction
BACKGROUND Lowering the diagnostic threshold for troponin is controversial because it may disproportionately increase the diagnosis of myocardial infarction in patients without acute coronary syndrome. We assessed the impact of lowering the diagnostic threshold of troponin on the incidence, management, and outcome of patients with type 2 myocardial infarction or myocardial injury. METHODS Con...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Vascular Health and Risk Management
سال: 2014
ISSN: 1178-2048
DOI: 10.2147/vhrm.s63416