DIANTIPYRYLPROPYLMETHANE AS ELECTRODE-ACTIVE COMPONENTS OF MEMBRANE OF LEAD SELECTIVE ELECTRODE

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Manganese (M-selective PVC membrane electrode based on N-(2- picolinamido ethyl)-Picolinamide as ionophore

In this research, a PVC membrane electrode for Manganese (II) ions based on N-(2-Picolinamidoethyl)Picolinamide as neutral carrier was prepared. The electrode exhibits a Nemstian responseover Mn(II) concentration range of (1.0 x10-5 t01.0 X 10-1M) with a slope of 29.3±0.5 mV perdecade of concentration with a working pH range of 4.0-9.0. It has a fast response time (

متن کامل

Selective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.

A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...

متن کامل

High-Sensitive and Selective Liquid Membrane Electrode for Direct Determination of Trace Amounts of Chromium

N-(2H-[1,2,4]thiadiazolo[2,3-a]pyridine-2-ylidene)benzamide was used as a selective sensing material in the PVC membrane to construction of a new chromium ion selective electrode. This liquid membrane electrode worked well with a Nernstian response of 19.7 ±0.4 mV decade-1 of Cr(III) in a wide dynamic concentration range of 8.0× 10-6-1.0×10-1 M. The electrode had relatively short response time ...

متن کامل

Using electrochemical impedance spectroscopy of salicylate anion selective electrode: simulation for behavior of electrode

In this paper, the behavior of the salicylate anion-selective electrode was studied using the electrochemical impedance spectroscopy technique. Considering the diagram of the charge transfer resistance and -logarithm of the double layer capacitance versus -logarithm of the concentration, linear range concentration increased to 1.0×10^{-8}-1.0×10^{-1} M and 1.0×10^{-9}-1.0×10^{-1} M, respectivel...

متن کامل

Lead(II)-selective electrode based on phenyl disulfide.

A PVC membrane electrode for lead ions based on phenyl disulfide as the membrane carrier was developed. The electrode exhibits a good Nernstian slope of 29.3 +/- 0.7 mV/decade and a linear range of 2.0 x 10(-6)-1.0 x 10(-2) M for Pb(NO3)2. The limit of detection is 1.2 x 10(-6) M. It has a response time of 45 s and can be used for at least fifty days without any divergence in potential. The pro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENIY KHIMIYA KHIMICHESKAYA TEKHNOLOGIYA

سال: 2018

ISSN: 2500-3070,0579-2991

DOI: 10.6060/tcct.20186102.5607