Dimensional Accuracy of Stone Casts Obtained with Multiple Pours into the Same Mold

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dimensional Accuracy of Stone Casts Obtained with Multiple Pours into the Same Mold

Aim. The aim of the present study was to compare the dimensional accuracy of stone casts obtained with vinyl polysiloxane molds through the double-impression technique with three pours into the same mold. Methods. A stainless steel master model was constructed simulating a three-unit fixed prosthesis. Twelve impressions were taken of this master model with addition silicone, using the double-im...

متن کامل

Accuracy of stone casts obtained by different impression materials.

Several impression materials are available in the Brazilian marketplace to be used in oral rehabilitation. The aim of this study was to compare the accuracy of different impression materials used for fixed partial dentures following the manufacturers' instructions. A master model representing a partially edentulous mandibular right hemi-arch segment whose teeth were prepared to receive full cro...

متن کامل

Elastomeric impression materials: a comparison of accuracy of multiple pours.

AIM The aim of the present study is to compare the various elastomeric impression materials in terms of accuracy and dimensional stability, with respect to obtaining multiple casts from a single elastomeric impression at various times of pours. MATERIALS AND METHODS Three master dies were prepared for the impression making, two of these were made of brass containing a central hole with underc...

متن کامل

effect of different impression materials and techniques on the dimensional accuracy of implant defi nitive casts

background: different factors such as impression techniques and materials can affect the passive fi t between the superstructure and implant. the aim of this study was to determine the effect of different impression materials and techniques on the dimensional accuracy of implant defi nitive casts. materials and methods: four internal hex implants (biohorizons ø4 mm) were placed on a metal maxil...

متن کامل

the effects of error correction methods on pronunciation accuracy

هدف از انجام این تحقیق مشخص کردن موثرترین متد اصلاح خطا بر روی دقت آهنگ و تاکید تلفظ کلمه در زبان انگلیسی بود. این تحقیق با پیاده کردن چهار متد ارائه اصلاح خطا در چهار گروه، سه گروه آزمایشی و یک گروه تحت کنترل، انجام شد که گروه های فوق الذکر شامل دانشجویان سطح بالای متوسط کتاب اول passages بودند. گروه اول شامل 15، دوم 14، سوم 15 و آخرین 16 دانشجو بودند. دوره مربوطه به مدت 10 هفته ادامه یافت و د...

15 صفحه اول

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: ISRN Dentistry

سال: 2012

ISSN: 2090-438X

DOI: 10.5402/2012/730674