Diode-based transmission detector for IMRT delivery monitoring: a validation study
نویسندگان
چکیده
منابع مشابه
Diode‐based transmission detector for IMRT delivery monitoring: a validation study
The purpose of this work was to evaluate the potential of a new transmission detector for real-time quality assurance of dynamic-MLC-based radiotherapy. The accuracy of detecting dose variation and static/dynamic MLC position deviations was measured, as well as the impact of the device on the radiation field (surface dose, transmission). Measured dose variations agreed with the known variations...
متن کاملconstruction and validation of a computerized adaptive translation test (a receptive based study)
آزمون انطباقی رایانه ای (cat) روشی نوین برای سنجش سطح علمی دانش آموزان می باشد. در حقیقت آزمون های رایانه ای با سرعت بالایی به سمت و سوی جایگزین عملی برای آزمون های کاغذی می روند (کینگزبری، هاوسر، 1993). مقاله حاضر به دنبال آزمون انطباقی رایانه ای برای ترجمه می باشد. بدین منظور دو پرسشنامه مشتمل بر 55 تست ترجمه میان 102 آزمودنی و 10 مدرس زبان انگلیسی پخش گردید. پرسشنامه اول میان 102 دانشجوی س...
Phase Frequency Detector Using Transmission Gates for High Speed Applications
In this paper a new phase-frequency detector is proposed using transmission gates which can detect phase difference less than 500ps. In other word, the proposed Phase-frequency Detector (PFD) can work in frequencies higher than 1.7 GHz, whereas a conventional PFD operates at frequencies less than 1.1 GHz. This new architecture is designed in TSMC 0.13um CMOS Technology. Also, the proposed PFD a...
متن کاملEvaluation of a 2D diode array for IMRT quality assurance.
BACKGROUND AND PURPOSE The QA of intensity modulated radiotherapy (IMRT) dosimetry is a laborious task. The goal of this work is to evaluate the dosimetric characteristics of a new 2D diode array (MapCheck from Sun Nuclear Corporation, Melbourne, Florida) and assess the role it can play in routine IMRT QA. MATERIAL AND METHODS Fundamental properties of the MapCheck such as reproducibility, li...
متن کاملValidation of the RightLevelpH Detector for Monitoring Gastric pH.
BACKGROUND The RightLevelpH indicator is a new device designed to measure the pH of gastric aspirate obtained via a nasogastric tube while minimizing exposure of the operator. OBJECTIVE To validate the RightLevelpH indicator in vivo and in vitro. METHODS With general anesthesia, 20 patients had placement of a nasogastric tube and a gastric pH electrode catheter after endotracheal intubation...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Applied Clinical Medical Physics
سال: 2016
ISSN: 1526-9914
DOI: 10.1120/jacmp.v17i5.6204