Direct Sampling in Air of Capillary Electrophoresis

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct sampling in air of capillary electrophoresis.

Capillary electrophoresis (CE) is usually off-line combined with an adsorption/desorption method to analyze gaseous or atmospheric samples. Here, we demonstrated direct sampling in the air of CE. The inlet end of a fused silica capillary filled with a pH 7.2 phosphate buffer was placed in the air for absorbing gaseous or volatile components, while the outlet end was immersed into a buffer vial ...

متن کامل

Sampling efficiency of a single-cell capillary electrophoresis system.

Capillary electrophoresis (CE) combined with a laser-induced fluorescence (LIF) detection scheme is a powerful approach for single-cell analysis. For measurements requiring a high temporal resolution, CE-LIF is often combined with cell lysis systems based on pulsed lasers. Although extremely rapid, laser lysis has raised some concerns about the efficiency at which the cell contents are sampled....

متن کامل

Gel Electrophoresis in Capillary Electrophoresis

The discovery that antigen}antibody interaction could be produced not only in liquids, but also on gel media, such as agar or agarose gels, with the formation of insoluble immunoprecipitates, opened the door to the development of the gel diffusion techniques for immunoprecipitation analysis. The Rrst of these techniques, known as double diffusion, was introduced by Ouchterlony in 1948. In this ...

متن کامل

Capillary electrophoresis microchip for direct amperometric detection of DNA fragments.

Detection and quantitation of nucleic acids have gained much importance in the last couple of decades, especially in the post-human genome project era. Such processes are tedious, time consuming and require expensive reagents and equipment. Therefore, in the present study, we demonstrated a simple process for the separation and analysis of small DNA fragments using capillary electrophoretic amp...

متن کامل

A stability indicating capillary electrophoresis method for analysis of buserelin

A simple and rapid stability indicating method based on capillary zone electrophoresis has been developed and validated for the analysis of buserelin (BUS). The best separations were achieved by using a bare fused silica capillary (75 m i.d.; 65.5 cm total, 57.0 cm effective length), phosphate buffer (pH = 3.00; 26.4 mM), at 35 °C. The sample was hydrodynamically injected at 50 mbar for 5 seco...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Analytical Sciences

سال: 2013

ISSN: 0910-6340,1348-2246

DOI: 10.2116/analsci.29.373