Disappearing high velocity severe tricuspid regurgitation following Ventricular septal defect device closure
نویسندگان
چکیده
منابع مشابه
Device fracture and severe tricuspid regurgitation after percutaneous closure of perimembranous ventricular septal defect: a case report.
We report a case in which fracture of an Amplatzer perimembranous ventricular septal defect (VSD) device occurred within 1 month after placement. This was associated with severe tricuspid regurgitation. Surgical removal of the device and repair of the tricuspid valve was performed with reasonable outcome. We propose a hypothesis on how this complication might have occurred and how it could be p...
متن کاملInvestigation of membranous ventricular septal defect complicated with tricuspid regurgitation in ventricular septal defect occlusion
This study aimed to explore the mechanism of membranous ventricular septal defect complicated with tricuspid regurgitation and the significance of ventricular septal defect occlusion by echocardiography. A total of 43 patients with membranous ventricular septal defect complicated with tricuspid regurgitation were observed by echocardiography and the changes in length, area and volume of tricusp...
متن کاملSevere heart failure in child with ventricular septal defect and acute tricuspid regurgitation.
A case is reported in which acute tricuspid regurgitation developed in a child with a ventricular septal defect resulting in a left ventricular-right atrial shunt. This was successfully treated by closure of the defect and tricuspid valve replacement. The anterior leaflet of the tricuspid valve was almost completely destroyed by endocarditis, though in previous reports of tricuspid valve endoca...
متن کاملright ventricular outflow tract obstruction diagnosed after percutaneous ventricular septal defect device closure
-
متن کامل[Percutaneous closure of ventricular septal defect with an Amplatzer device].
We present a series of 4 patients in whom a ventricular septal defect (VSD) was closed with an Amplatzer muscular VSD device during cardiac catheterization. In one patient with type I truncus arteriosus and subarterial VSD, closure of a wide apical defect was done to allow further surgical correction while avoiding left ventricular ventriculotomy. The second patient had congenitally corrected t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Indian Heart Journal
سال: 2017
ISSN: 0019-4832
DOI: 10.1016/j.ihj.2017.01.001