Discrete Iterative Partial Segmentation Technique (DIPS) for Tomographic Reconstruction

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of discrete-to-discrete imaging models for iterative tomographic image reconstruction and compressive sensing

Discrete-to-discrete imaging models for computed tomography (CT) are becoming increasingly ubiquitous as the interest in iterative image reconstruction algorithms has heightened. Despite this trend, all the intuition for algorithm and system design derives from analysis of continuous-to-continuous models such as the X-ray and Radon transform. While the similarity between these models justifies ...

متن کامل

Adaptive Sparsifying Transforms for Iterative Tomographic Reconstruction

A major challenge in computed tomography imaging is to obtain high-quality images from low-dose measurements. Key to this goal are computationally efficient reconstruction algorithms combined with detailed signal models. We show that the recently introduced adaptive sparsifying transform (AST) signal model provides superior reconstructions from low-dose data at significantly lower cost than com...

متن کامل

Novel Segmentation Technique for Measured Three-Phase Voltage Dips

1 Electronic Technology Area, University of Cordoba, Cordoba 14002, Spain; E-Mails: [email protected] (A.M.-M.); [email protected] (A.G.-C.) 2 Electric Power Engineering, Department of Engineering Sciences and Mathematics, Luleå University of Technology, Skellefteå 931 87, Sweden; E-Mail: [email protected] 3 Department of Signals and Systems, Chalmers University of Technology, Göteborg 412 58, Sweden; ...

متن کامل

3D Iterative Tomographic Reconstruction Using Graphics Processors

An original parallel computional algorithm is developed for 3D tomographic reconstruction in a conic beam based on graphics processors. DOI: 10.1134/S1061830909080117

متن کامل

Iterative reconstruction with segmentation penalty for PET.

Segmentation technique is widely accepted to reduce noise propagation from transmission scanning for positron emission tomography. The conventional routine is to sequentially perform reconstruction and segmentation. A smoothness penalty is also usually used to reduce noise, which can be imposed to both the ML and WLS estimators. In this paper we replace the smoothness penalty by a segmentation ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Computational Imaging

سال: 2016

ISSN: 2333-9403,2334-0118

DOI: 10.1109/tci.2016.2521340