Displacement of Pile-Reinforced Slopes with a Weak Layer Subjected to Seismic Loads
نویسندگان
چکیده
منابع مشابه
Sensitivity analysis of pile-founded fixed steel jacket platforms subjected to seismic loads
The sensitivity of the seismic response parameters to the uncertain modeling variables of pile-founded fixed steel jacket platforms are investigated using the Tornado diagram and the first-order second-moment techniques. The effects of both aleatory and epistemic uncertainty on seismic response parameters have been investigated for an existing offshore platform. The sources of uncertainty consi...
متن کاملSeismic Bearing Capacity of Strip Footings on Pile-Stabilized Slopes
This paper develops an analytical method to calculate seismic bearing capacity of a strip footing, which is located on a slope reinforced with rows of pile. The resistance of passive pile is determined based on normal and shear stress of the soil around the pile, which is then compared to other analytical methods. This comparison indicates an acceptable agreement. The variants of the study incl...
متن کاملseismic bearing capacity of strip footings on pile-stabilized slopes
this paper develops an analytical method to calculate seismic bearing capacity of a strip footing, which is located on a slope reinforced with rows of pile. the resistance of passive pile is determined based on normal and shear stress of the soil around the pile, which is then compared to other analytical methods. this comparison indicates an acceptable agreement. the variants of the study incl...
متن کاملEffects of Weak Layer Angle and Thickness on the Stability of Rock Slopes
This paper researches two key factors (angle and thickness) of a weak layer in relation to their influencing mechanism on slope stability. It puts forward the sliding surface angle and morphological model criteria for the control of rock slopes and realization of its failure mechanism. By comparing the Failure Modes and Safety Factors (Fs) obtained from numerical analysis, the influence pattern...
متن کاملBehavior of Steel-Sheathed Shear Walls Subjected to Seismic and Fire Loads.
A series of tests was conducted on six 2.7 m × 3.7 m shear wall specimens consisting of cold-formed steel framing sheathed on one side with sheet steel adhered to gypsum board and on the opposite side with plain gypsum board. The specimens were subjected to various sequences of simulated seismic shear deformation and fire exposure to study the influence of multi-hazard interactions on the later...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Mathematical Problems in Engineering
سال: 2016
ISSN: 1024-123X,1563-5147
DOI: 10.1155/2016/1527659