Distance protection of EHV long transmission lines considering compensation degree of shunt reactor

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of CT and VT Connection Point on Distance Protection of Transmission Lines with FACTS Devices

This paper presents the effects of instrument transformers connection points on the measured impedance by distance relays in the presence of Flexible Alternating Current Transmission System (FACTS) devices with series connected branch. Distance relay tripping characteristic itself depends on the power system structural conditions, pre-fault operational conditions, and especially the ground ...

متن کامل

Adaptive ground distance protection for UPFC compensated transmission lines: A formulation considering the fault resistance effect

This paper presents a mathematical deterministic adaptive distance protection formulation for UPFC compensated transmission lines. The proposed formulation is developed using a phase component approach and considers and compensates for various UPFC operation conditions and non-zero fault resistances. The proposed methodology is completely adaptive and independent of system characteristics (such...

متن کامل

Distance Protection Scheme For Protection of Long Transmission Line Considering the Effect of Fault Resistance By Using the ANN Approach

Traditional electromechanical distance relays used for protection of transmission lines are prone to effects of fault resistance. Each fault condition corresponds to a particular pattern. So use of a pattern recognizer can improve the relay performance. This paper presents a new approach, known as artificial neural network (ANN) to overcome the effect of fault resistance on relay mal-operation....

متن کامل

Lightning Protection of Ehv Substations in Iran

Extra high voltage (EHV) substations are extremely vulnerable to the hazard of lightning strokes therefore, the shielding of these substations with a highly reliable protective scheme (shield wires) is an essential undertaking. In this paper an attempt is made to clarify the design procedure for shielding EHV substations against lightning with special reference to Iran.

متن کامل

Delft University of Technology Shunt Compensation Design of EHV Double-Circuit Mixed OHL-Cable Connections

This paper deals with the shunt compensation design of long 380kV-50Hz XLPE cables by simulating a double-circuit partially cabled connection with the transmission length of 80 km in the Dutch transmission system. The proposed procedure for shunt compensation sizing is fully elaborated in this paper. Four sizing criteria are used to find the minimum required size of compensation. All simulation...