DistoX calibration tools and the need for calibration checking

نویسندگان

چکیده

For proper cave surveying using DistoX, the device needs to be calibrated with adequate accuracy. Calibrating does not require any tools; but, tools make calibration easier have been developed. Theoretical consideration shows that use of certain enables one introduce a type error goes undetected by software. In this study, existence such errors is experimentally confirmed and their magnitude estimated. It demonstrated crucial DistoX valid, is, has changed since it was last calibrated. No part must moved or its magnetization calibration, even battery. The method used quality resulting are important too. highly recommended checked immediately before thus avoid possibility an uncalibrated, validly calibrated, poorly device. To complete check, few survey shots measured multiple times at different roll angles, back shot measured. If properly measurements will agree each other within acceptable measurement error. This case for

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calibration with Many Checking Rules

Each period an outcome (out of finitely many possibilities) is observed. For simplicity assume two possible outcomes, a and b. Each period, a forecaster announces the probability of a occurring next period based on the past. Consider an arbitrary subsequence of periods (e.g., odd periods, even periods, all periods in which b is observed, etc). Given an integer n, divide any such subsequence int...

متن کامل

Calibration of Load and Resistance Factors for Reinforced Concrete

Current approach for designing of reinforced concrete members is based on the load and resistance factor. However the load and resistance parameters are random variables, the constant values have been designated for them in the designing procedure. Assuming these factors as the constants, will be led to the unsafe and uneconomical designs. Safe designing of structures requires appropriate recog...

متن کامل

Calibration of Hardening Rules for Cyclic Plasticity

In the realm of multi-axial ratcheting, a step by step mathematical approach is developed for the parameter determination of decomposed kinematic hardening rules. For this purpose, key characteristics are mathematically derived for these hardening rules under multi-axial loading. These characteristics are then utilized to develop expressions which relate the loading history to the accumulated p...

متن کامل

The Need for a Shear Stress Calibration Standard

By surveying current research of various micro-electro mechanical systems (MEMS) shear stress sensor development efforts we illustrate the wide variety of methods used to test and characterize these sensors. The different methods of testing these sensors make comparison of results difficult in some cases, and also this comparison is further complicated by the different formats used in reporting...

متن کامل

Colorimetric Scanner Calibration for Textiles by Neural-Network

In this study, colorimetric calibration of scanner has been done via perceptron neural network with three or four layers by back propagation algorithm for colored polyester fabrics. The results obtained for random training samples are not satisfactory but application of selective training samples for L*a*b* or RGB leads to good results, with better results obtained for the L*a*b* method. On the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Acta Carsologica

سال: 2021

ISSN: ['1580-2612', '0583-6050']

DOI: https://doi.org/10.3986/ac.v50i1.9653