Distraction osteogenesis with conventional external fixator for tibial bone loss

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Distraction osteogenesis using a monolateral external fixator for infected non-union of the femur with bone loss.

PURPOSE To review records of 15 patients who underwent distraction osteogenesis/bone transport using a monolateral external fixator for infected non-union of the femoral shaft. METHODS 13 men and 2 women aged 18 to 47 years underwent adequate debridement and resection of nonviable bone, followed by bone transport using a monolateral external fixator for infected non-union of the femoral shaft...

متن کامل

Distraction osteogenesis for tibial nonunion with bone loss using combined Ilizarov and Taylor spatial frames versus a conventional circular frame

This retrospective review assesses 55 tibial nonunions with bone loss to compare union achieved with combined Ilizarov and Taylor spatial frames (I-TSF) versus a conventional circular frame with the standard Ilizarov procedure. Seventeen (31 %) of the 55 nonunions were infected. Thirty patients treated with I-TSF were compared with 25 patients treated with a conventional circular frame. In the ...

متن کامل

Subsidence of callotasis zone in distraction osteogenesis after external fixator removal, measured by RSA

BACKGROUND AND PURPOSE In clinical practice, achieved lengthening of a callotasis zone should be maintained after the external fixator has been removed. The common understanding has been that the regenerated bone may subside. To investigate this, we used high-resolution radiostereometric analysis (RSA) with accurate measurement of the lengthening zone. PATIENTS AND METHODS We assessed the lon...

متن کامل

Anesthetic concerns of external maxillary distraction osteogenesis.

BACKGROUND External maxillary distractions present additional anesthetic concerns to the existing complexity of the patient with craniofacial disorder. The distraction hardware is rigidly fixed to the cranium and projects in the frontofacial midline, thus limiting oronasal airway access. METHODS A review of 16 patients (10 male, 6 female) having external maxillary distraction was done. Patien...

متن کامل

Open Tibial Shaft Fractures; Treatment with External Fixator

.. Objective: The purpose of the study was to evaluate the clinical results after operative treatment of open tibia fractures (grade IIIA/B) with external fixator. Material and methods: 25 patients with open fractures of the tibial diaphysis, classified as type III A and B, according to the Gustilo classification, were operatively treated in Agency Headquarter Hospital Landikotal. All the patie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Orthopaedics

سال: 2004

ISSN: 0341-2695,1432-5195

DOI: 10.1007/s00264-004-0553-2