Distributed Multiple Tuned Mass Dampers for Wind Vibration Response Control of High-Rise Building

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tuned Mass Dampers for Earthquake Vibrations of High-rise Buildings using Bee Colony Optimization Technique

This paper investigates the application of Artificial Bee Colony (ABC) method for the optimization of Tuned Mass Dampers (TMDs) employed for high-rise structures including Soil Structure Interaction (SSI). The model is a 40-story building, and Newmark method is utilized for the structure response to Bam earthquake data. The objective is to decrease both maximum displacement and accelerati...

متن کامل

dual-layer multiple tuned mass dampers for vibration control of structures

the performance of dual-layer multiple tuned mass dampers (dl-mtmd) with uniformly distributed natural frequencies is investigated. the dl-mtmd consists of one large tuned mass damper (l-tmd) and an arbitrary number of small tuned mass dampers (s-tmd). the primary structure is represented as a single degree-of-freedom system which corresponds to a specific vibration mode to be controlled in a r...

متن کامل

«research note» vibration control of high-rise buildings with tuned mass dampers (case study: tehran international tower)

abstract: appealing to the principle of vertical residence and stemming the horizontal expansion of the city, the tehran milad tower is being built on 35000 sm3 site with the total area of 220000 sm3. with a height of over 170m, this 56-story concrete building is in the final stages of construction and would be the highest residential building of iran. since tehran is located in a high-risk ear...

متن کامل

OPTIMIZED TUNED LIQUID COLUMN DAMPERS FOR EARTHQUAKE OSCILLATIONS OF HIGH-RISE STRUCTURES INCLUDING SOIL EFFECTS

This paper investigates the optimized parameters for the tuned liquid column dampers to decrease the earthquake vibrations of high-rise buildings. Considering soil effects, the soilstructure interaction (SSI) is involved in this model. The Tuned Liquid Column Damper (TLCD) is also utilized on the roof of the building. Since the TLCD is a nonlinear device, the time domain analysis based on nonli...

متن کامل

Semiactive Tuned Mass Dampers

Studies have already demonstrated the successful use of linear semiactive damping devices, such as variable orifice (VO) dampers, for semiactive TMD systems. More recently, nonlinear semiactive damping devices, such as magnetorheological (MR) dampers, have also been shown to be effective for semiactive control of TMDs. Though semiactive dampers differ widely, with responses ranging from linear ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Engineering

سال: 2014

ISSN: 2314-4904,2314-4912

DOI: 10.1155/2014/198719