Distribution of standing-wave errors in real-ear sound-level measurements.
Standing waves can cause measurement errors when sound-pressure level (SPL) measurements are performed in a closed ear canal, e.g., during probe-microphone system calibration for distortion-product otoacoustic emission (DPOAE) testing. Alternative calibration methods, such as forward-pressure level (FPL), minimize the influence of standing waves by calculating the forward-going sound waves sepa...
متن کاملStanding Wave Oscillators for Global Clock Distribution
The clock signal of modern computer processors consumes a large portion of overall chip power. By modeling global clock network wires as transmission lines and manipulating their dimensions, the global clock signal can be transformed into a standing-wave oscillator that conserves energy and reduces skew. This paper explains the lossy transmission line model and explores the effects of matching ...
متن کاملSound level measurements in music practice rooms
Average sound levels and percentage of daily dose of noise exposure were measured in the practice rooms of a university school of music, with the primary objective of determining whether sound levels in student practice rooms were high enough to warrant concern for hearing conservation. A secondary objective was to determine whether any instrument group was at higher risk for music-induced hear...
متن کاملIntersubject variability of real-ear sound pressure level: conventional and insert earphones.
Measures of the sound pressure level (SPL) near the eardrum were determined at discrete frequencies between 500 and 4000 Hz on 50 ears using TDH-39P and ER-3A earphones with the attenuator of an audiometer fixed at 90 dB HL. Results revealed significant differences in the measured SPL between the two earphones at all test frequencies. Results also revealed large intersubject differences in the ...
متن کاملIn-Ear Pulse Wave Measurements: A Pilot Study.
The measurement of the Pulse wave Arrival Time (PAT) has proven to be a vital tool in medical diagnosis. Whereby most PAT measurements are carried out at extremities, this work proposes the interior of the ear as a new site. Due to pressure variations inside the auditory canal a pulse wave can be measured by using a pressure sensor or by simple in-ear headphones. To verify the signal origin, a ...