Does a Shortened Hyperemia With Regadenoson Stress Pose a Concern for Quantitative Rb-82 PET Imaging?
نویسندگان
چکیده
منابع مشابه
Does a shortened hyperemia with regadenoson stress pose a concern for quantitative Rb-82 PET imaging? Optimization of regadenoson PET imaging.
A lthough regadenoson has nearly replaced other vasodilator stressors for single-photon emission computed tomography perfusion imaging, the benefits of regadenoson stress for positron emission tomography (PET) perfusion are less clearly established, particularly in the estimation of absolute stress flow with dynamic PET imaging. In the estimation of absolute flow with dynamic PET, the timing of...
متن کاملRegadenoson versus dipyridamole hyperemia for cardiac PET imaging.
OBJECTIVES The goal of this study was to compare regadenoson and dipyridamole hyperemia for quantitative myocardial perfusion imaging. BACKGROUND Regadenoson is commonly used for stress perfusion imaging. However, no study in nuclear cardiology has employed a paired design to compare quantitative hyperemic flow from regadenoson to more traditional agents such as dipyridamole. Additionally, th...
متن کاملReproducibility and accuracy of quantitative myocardial blood flow assessment with (82)Rb PET: comparison with (13)N-ammonia PET.
UNLABELLED (82)Rb cardiac PET allows the assessment of myocardial perfusion with a column generator in clinics that lack a cyclotron. There is evidence that the quantitation of myocardial blood flow (MBF) and coronary flow reserve (CFR) with dynamic (82)Rb PET is feasible. The objectives of this study were to determine the accuracy and reproducibility of MBF estimates from dynamic (82)Rb PET by...
متن کاملTherapy response assessment with quantitative PET: evaluation of a shortened acquisition protocol with dynamic PET/CT
Material and methods 13 patients with histopathologically proven oesophageal adenocarcinoma underwent a combined dynamic and static F-FDG PET/CT including CT tumour perfusion (Siemens, Biograph mCT). Dynamic PET (listmode) was acquired for 60 min resulting in 38 frames from 10 to 600 sec duration for the full dynamic dataset and 2 frames each with 600 sec duration (20-30 min and 50-60 min p.i.)...
متن کاملEstablishing the prognostic value of Rb-82 PET myocardial perfusion imaging: a step in the right direction.
In the last decade, positron emission tomography (PET) myocardial perfusion imaging (MPI) has emerged as a valuable clinical tool for the management of patients with known or suspected coronary artery disease (CAD). Compared with singlephoton emission computed-tomography (SPECT), PET provides higher-quality images and superior diagnostic accuracy (1). Increased availability of PET scanners, Med...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: JACC: Cardiovascular Imaging
سال: 2015
ISSN: 1936-878X
DOI: 10.1016/j.jcmg.2014.12.022