Does billowing of the Endologix Powerlink Stent Graft correlate with decrease in aneurysm sac size?

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Billowing Of Endologix Powerlink Stent Mimicking Endoleaks.

INTRODUCTION Endoleaks remains one of the primary concerns of endovascular aortic aneurysm repair (EVAR) and is routinely followed with CT angiography (CTA). However, certain imaging findings can mimic endoleaks. CASE PRESENTATION A 65-year-old woman who had endovascular aortic repair (EVAR) of an abdominal aortic aneurysm with Endologix Powerlink system developed marked new circumferential c...

متن کامل

billowing of endologix powerlink stent mimicking endoleaks

conclusions considering the unique construct of the powerlink stents, this is thought to represent aneurysmal degeneration of the outer fabric material from the metal struts and may potentially pressurize the excluded sac with risk for rupture. case presentation a 65-year-old woman who had endovascular aortic repair (evar) of an abdominal aortic aneurysm with endologix powerlink system develope...

متن کامل

Management of a large coronary artery aneurysm with graft-coated stent during the acute phase of myocardial infarction

Coronary aneurysms in adults are rare clinical entities. Herein, we presented a 54-year-old man who was admitted with an acute extensive anterior myocardial infarction. The emergency coronary angiography revealed an isolated large aneurysm at the proximal segment of the left anterior descending coronary artery. The patient was successfully treated with a graft-coated stent

متن کامل

Lateral movement of endografts within the aneurysm sac is an indicator of stent-graft instability.

PURPOSE To determine if lateral movement of an aortic endograft 1 year following endovascular abdominal aortic aneurysm (AAA) repair is an indicator of endograft instability and can serve as a predictor of late adverse events. METHODS The records of 60 high-risk AAA patients (52 men, 8 women; mean age 74 years) who were treated with infrarenal (n = 38) or suprarenal (n = 22) endografts and ha...

متن کامل

12-year Experience with the Endologix Powerlink Device in Endovascular Repair of Abdominal Aortic Aneurysms

Since Parodi reported the first successful endovascular aneurysm repair procedure in 1991, this procedure has gained wide acceptance for the treatment of abdominal aortic aneurysms in the past two decades. This minimally invasive approach has been proven effective and safe in the treatment of abdominal aortic aneurysm patients with lower early morbidity and mortality rates compared to open surg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Vascular and Interventional Radiology

سال: 2016

ISSN: 1051-0443

DOI: 10.1016/j.jvir.2015.12.532