Does Collagenase Affect the Electrophysiological Parameters of Nerve Trunk?
نویسندگان
چکیده
منابع مشابه
[Does collagenase affect the electrophysiological parameters of nerve trunk?].
Collegenase is widely used in the process of teasing a nerve in order to perform single fiber action potential (SFAP) recordings. In this study, the effects of collagenase on nerve conduction parameters were investigated. To accomplish this, normal compound action potentials (nCAPs) were recorded from isolated frog sciatic nerve at various distances using the suction technique. Then, the same n...
متن کاملDoes fluid restriction affect the image quality of skeletal scintigraphy?
Introduction: In Islamic countries in the month of Holy Ramadan many Muslims based on their religious Legislation refuse fluid intake during the fasting time though instructed to drink after injection of Tc-99m Methylene-diphosphonates [Tc-99m MDP] used for skeletal scintigraphy. We aimed to establish whether fluid restriction in Tc-99m MDP skeletal scintigraphy has an impact on its quality. M...
متن کاملLimb immobilization alters functional electrophysiological parameters of sciatic nerve
Immobilization, used in clinical practice to treat traumatologic problems, causes changes in muscle, but it is not known whether changes also occur in nerves. We investigated the effects of immobilization on excitability and compound action potential (CAP) and the ultrastructure of the rat sciatic nerve. Fourteen days after immobilization of the right leg of adult male Wistar rats (n=34), anima...
متن کاملDoes High Frequency Transcutaneous Electrical Nerve Stimulation (TENS) Affect EEG Gamma Band Activity?
Background: Transcutaneous electrical nerve stimulation (TENS) is a noninvasive, inexpensive and safe analgesic technique used for relieving acute and chronic pain. However, despite all these advantages, there has been very little research into the therapeutic effects of TENS on brain activity. To the best of our knowledge, there is no evidence on the effect of high frequency TENS on the gamma ...
متن کاملDoes body posture affect the parameters of a cutaneous electrogastrogram?
In a study aimed to test the effect of body position on the parameters derived from surface electrogastrograms, 17 healthy volunteers (2M, 15F; median age 22.5 years) attended in random order two examination sessions held on separate days. A 30-min recording of the interdigestive gastric myoelectrical activity (GMA) was followed by a 90-min postprandial recording after intake of a 394 kcal mixe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: YAKUGAKU ZASSHI
سال: 2003
ISSN: 0031-6903,1347-5231
DOI: 10.1248/yakushi.123.1031