Does low-intensity pulsed ultrasound stimulate maturation of tissue-engineered cartilage?
نویسندگان
چکیده
منابع مشابه
Does low-intensity pulsed ultrasound stimulate maturation of tissue-engineered cartilage?
Traumatic events are a primary cause of local lesions of articular cartilage. Tissue engineered, cartilage-like structures represent an alternative to current treatment methods. The time necessary for tissue maturation and the mechanical quality of the regenerate at implantation are both critical factors for clinical success. Low-intensity pulsed ultrasound has proven to accelerate chondrogenes...
متن کاملDoes Low-intensity pulsed ultrasound treatment repair articular cartilage injury? A rabbit model study
BACKGROUND Low-intensity pulsed ultrasound (LIPUS) regiment has been used to treat fractures with non-union and to promote bone union in general. The effect of LIPUS on articular cartilage metabolism has been characterized. Yet, the effect of LIPUS to repair articular cartilage injury remains unclear in vivo. METHODS We designed a study to investigate the effect of LIPUS on articular cartilag...
متن کاملLOW INTENSITY PULSED ULTRASOUND TREATMENT INCREASES RABBIT RADIAL FRACTURE HEALING
In order to study the effect of ultrasound (US) on bone healing, a complete transverse fracture was made in the right radius of adult male rabbits by a cutter. 52 rabbits were used: group I. control (n= 17): group 2. test (n:=: 15): group 3, intact (n= I) and group 4 (n= 12) who were examined only for evaluation of the cutter effects in detail. 7 animals were operated with a Gigli saw. The ...
متن کاملLow Intensity Pulsed Ultrasound (LIPUS)
The application of ultrasound energy at much lower levels than is the current clinical norm is starting to gain ground as a therapeutic possibility. Clearly the applied energy is the same, it is the ‘dose’ which is different – most importantly, the intensity (W cm) – which is MUCH lower – typically 2 or 3 times lower than the lowest setting on most regular clinical machines, with the most commo...
متن کاملLow Intensity Pulsed Ultrasound (LIPUS)
The application of ultrasound energy at much lower levels than is the current clinical norm is starting to gain ground as a therapeutic possibility. Clearly the applied energy is the same, it is the ‘dose’ which is different – most importantly, the intensity (W/cm) – which is MUCH lower – typically 2 or 3 times lower than the lowest setting on most regular clinical machines, with the most commo...