Dose Computation of Keloids in Brachytherapy: Tg-43 or Model-Based-Dose-Calculation?

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determining TG-43 brachytherapy dosimetry parameters and dose distribution for a 131Cs source model CS-1

Background: Monte Carlo determination of TG-43 brachytherapy dosimetry parameters and dose distribution calculation for 131Cs source model CS-1 are presented in this study. Materials and Methods: The dose distribution was calculated around the 131Cs Model CS-1 located in the center of 30 cm ×30 cm ×30 cm water, and soft tissue phantoms cube using MCNP code by Monte Carlo method. The percentage ...

متن کامل

determining tg-43 brachytherapy dosimetry parameters and dose distribution for a 131cs source model cs-1

background: monte carlo determination of tg-43 brachytherapy dosimetry parameters and dose distribution calculation for 131cs source model cs-1 are presented in this study. materials and methods: the dose distribution was calculated around the 131cs model cs-1 located in the center of 30 cm ×30 cm ×30 cm water, and soft tissue phantoms cube using mcnp code by monte carlo method. the percentage ...

متن کامل

Determining TG-43 brachytherapy dosimetry parameters and dose distribution for a 131Cs source model CS-1

Theoretical and experimental dosimetric studies have been supplied useful information on the dependence of the brachytherapy source geometry and materials (1-5). Usually, Monte Carlo method is used to define dose distribution function, the radial dose variation, and the dose calculation close to the source in brachytherapy. Chen et al. (6). calculated the distribution of absorbed dose around co...

متن کامل

Erratum: “Cylindrical coordinate‐based TG‐43U1 parameters for dose calculation around elongated brachytherapy sources”

i) The institutional affiliation for co-author Manzoor Hussain is missing. The affiliation of Manzoor Hussain is University of the Punjab, Department of Physics, Jinnah Campus, Lahore, Pakistan. With this correction, the institutional affiliations of all the authors will be as follows: Shahid B. Awan,a,b Sharifeh A. Dinib, Manzoor Hussaina, David Soleimani-Meigoonib, and Ali S. Meigoonib Univer...

متن کامل

Cylindrical coordinate‐based TG‐43U1 parameters for dose calculation around elongated brachytherapy sources

In 2001, the use of cylindrical coordinates was demonstrated to be more suitable than was the use of polar coordinates for accurate computer calculations during treatment planning for 192Ir intravascular brachytherapy sources. In the present work, we investigated the applicability of cylindrical coordinate-based TG-43U1 parameters for dosimetric evaluation and dose calculations for RadioCoil 10...