Dose Linearity and Linear Energy Transfer Dependence of Cr-doped Al2O3 Ceramic Thermoluminescence Detector
نویسندگان
چکیده
منابع مشابه
Superlinear dose dependence of high temperature thermoluminescence peaks in Al2O3:C.
We report on strong superlinearity of high temperature (300-700 degrees C) thermoluminescence (TL) peaks in alpha-Al2O3:C powder. The main dosimetric peak at approximately 200 degrees C, previously found to exhibit slight superlinearity, is now shown to yield a slope of approximately 1.15 on a log(intensity) vs. log(dose) curve. Higher temperature peaks at approximately 320, 450 and 650 degrees...
متن کاملIntrinsic superlinear dose dependence of thermoluminescence and optically stimulated luminescence at high excitation dose rates
Superlinear dose dependence of thermoluminescence (TL) and optically stimulated luminescence (OSL) has been reported for many materials. The theoretical explanation has been ascribed to competition of either traps or recombination centers, during the excitation stage or during the read-out phase. There has been an account in the literature on superlinearity of OSL associated with merely one tra...
متن کاملHigh energy transmission of Al2O3 doped with light transition metals.
The transmission of transparent colored ceramics based on Al(2)O(3) doped with light transition metals is measured in the visible and infrared range. To clarify the role of the dopands we perform ab initio calculations. We discuss the electronic structure and present optical spectra obtained in the independent particle approximation. We argue that the gross spectral features of Co- and Ni-doped...
متن کاملSynthesis and Thermochromic Properties of Cr-Doped Al2O3 for a Reversible Thermochromic Sensor
An inorganic thermochromic material based on Cr-doped Al₂O₃ is synthesized using a solid-state method. The crystal structure, chemical composition, and morphology of the synthesized material are analyzed using X-ray diffraction, scanning electron microscopy coupled with an energy-dispersive X-ray spectrometer, and Fourier transform infrared (FT-IR) spectroscopy. The color performances of the sy...
متن کاملVerification of dose rate and energy dependence of MAGICA polymer gel dosimeter with electron beams
Background: The purpose of this study was to evaluate the dependency of MAGICA polymer gel dosimeter response (R2) on different electron energies as well as on different mean dose rate for a standard clinically used linear accelerator. Materials and Methods: The sensitivity of the dosimeter was represented by the slope of calibration curve in the linear region measured for each modalit...