Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part I. Electronic brachytherapy source

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part I. Electronic brachytherapy source.

PURPOSE Historically, treatment of malignant surface lesions has been achieved with linear accelerator based electron beams or superficial x-ray beams. Recent developments in the field of brachytherapy now allow for the treatment of surface lesions with specialized conical applicators placed directly on the lesion. Applicators are available for use with high dose rate (HDR)(192)Ir sources, as w...

متن کامل

Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part II. High dose rate 192Ir sources.

PURPOSE Historically, treatment of malignant surface lesions has been achieved with linear accelerator based electron beams or superficial x-ray beams. Recent developments in the field of brachytherapy now allow for the treatment of surface lesions with specialized conical applicators placed directly on the lesion. Applicators are available for use with high dose rate (HDR)(192)Ir sources, as w...

متن کامل

Dosimetric characterization of round HDR 192Ir accuboost applicators for breast brachytherapy.

PURPOSE The AccuBoost brachytherapy system applies HDR 192Ir beams peripherally to the breast using collimating applicators. The purpose of this study was to benchmark Monte Carlo simulations of the HDR 192Ir source, to dosimetrically characterize the round applicators using established Monte Carlo simulation and radiation measurement techniques and to gather data for clinical use. METHODS Do...

متن کامل

Determination of Dosimetric Characteristics of IrSeed 125I Brachytherapy Source

Introduction Low dose rate brachytherapy sources have been widely used for interstitial implants in tumor sites, particularly in prostate. Dosimetric characteristics of a new IrSeed 125I brachytherapy source have been determined using the LiF thermoluminescent dosimeter (TLD) chips. Materials and Methods Dose rate constant, radial dose function, and anisotropy function around the IrSeed 125I so...

متن کامل

Interface dosimetry for electronic brachytherapy intracavitary breast balloon applicators

In this study, we evaluate the attenuation of the dose due to barium-impregnation in the region between the surface of an electronic brachytherapy (EBT) balloon applicator for accelerated partial breast irradiation (APBI) and the prescription point at 1 cm depth in tissue. To perform the study, depth dose curves were calculated using a general purpose multi-particle transport code (FLUKA) for a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Medical Physics

سال: 2014

ISSN: 0094-2405

DOI: 10.1118/1.4862505