Dosimetric properties of a newly developed thermoluminescent sheet‐type dosimeter for clinical proton beams
نویسندگان
چکیده
منابع مشابه
Dosimetric study of thermoluminescent detectors in clinical photon beams using liquid water and PMMA phantoms.
The purpose of this study was the dosimetric evaluation of thermoluminescent detectors of calcium sulphate doped with dysprosium (CaSO4:Dy) produced by IPEN compared to the TL response of lithium fluoride doped with magnesium and titanium (LiF:Mg,Ti) dosimeters and microdosimeters produced by Harshaw Chemical Company to clinical photon beams dosimetry (6 and 15 MV) using liquid water and PMMA p...
متن کاملA search for novel thermoluminescent radiation dosimeter media.
We describe two example pilot efforts to help define new thermoluminescent dosimeter media. The first concerns ZnS:Mn nanophosphors, prepared by chemical precipitation using zinc and sodium sulfate, doped with manganese sulfate at concentrations varying from 1 to 3mol. The second concerns chemical vapor deposited diamond, produced as a thin film or as amorphous carbon on a single-crystal silico...
متن کاملdosimetric evaluation of a newly developed radiochromic film for radiation processing
in order to improve the performance of a newly developed radiochromic film, gic-79, somedosimetric characteristics of this film have been studied based on relevant standard practice. the presentstudy describes some parameters that may affect the dosimeter response before, during, and after irradiation. the effect of absorbed dose rate on dosimeter response was determined by irradiating dosimete...
متن کاملDosimetric assessment of the PRESAGE dosimeter for a proton pencil beam
The objective of this study is to assess the feasibility of using PRESAGE dosimeters for proton pencil beam dosimetry. Two different formulations of phantom materials were tested for their suitability in characterizing a single proton pencil beam. The dosimetric response of PRESAGE was found to be linear up to 4Gy. First-generation optical CT scanner, OCTOPUS was used to implement dose distribu...
متن کاملUse of light source for testing thermoluminescent dosimeter readers.
It is a common practice to check the performance of a TLD reader by inserting a light source composed of a phosphor mixed with a radioactive material, e.g., 14C . The response to the light source is used as a measure of a) the calibration or long-term stability of the reader and b) the ability of the reader to reproduce a constant signal. Usually the laboratory which measures a wide range of do...