Double infusion control
نویسندگان
چکیده
منابع مشابه
the efficacy of postoperative wound infusion with bupivacaine for pain control after cesarean delivery: randomized double blind clinical trial
objective: this study investigated the efficacy of bupivacaine wound infusion for pain control and opioid sparing effect after cesarean delivery. materials and methods: we conducted a randomized double blind, placebo controlled clinical trial on 60 parturients undergoing cesarean section at a university hospital in tehran. patients were randomized to receive a pump infusion system that was fill...
متن کاملA randomised double-blind control study of early intracoronary autologous bone marrow cell infusion in acute myocardial infarction (REGENERATE-AMI)
INTRODUCTION Acute myocardial infarction (AMI) remains a major cause of mortality and morbidity worldwide despite the latest therapeutic advances designed to decrease myocardial injury. Preclinical and emerging clinical evidence show that the intracoronary injection of autologous bone marrow mononuclear cells (BMCs) following AMI leads to improvement in left ventricular ejection function (LVEF)...
متن کاملAnalgesic Efficacy of Intravenous Lidocaine Infusion in Cesarean Section under Spinal Anesthesia: A Prospective Randomized Double-Blind Study
Background & Objective: Nowadays, conventional analgesic agents that are usually used for pain killing after cesarean sections do not provide enough analgesia with infrequent serious side effects. Lidocaine has been suggested as an adjuvant analgesic agent for postoperative pain relief. We designed this randomized double-blind, placebo-controlled study to evaluate the analgesic efficacy of intr...
متن کاملANFIS Control Double-Inverted Pendulum
For double inverted pendulum multivariable, strong coupling and nonlinear proposed adaptive fuzzy neural inference system (ANFIS) is applied inverted pendulum stabilization control process. Adaptive control algorithm, fully able to meet the requirements of double inverted pendulum control, ANFIS system after training, will be applied to the inverted pendulum system controller has better control...
متن کاملActive insulin infusion using optimal and derivative-weighted control.
Close control of blood glucose levels significantly reduces vascular complications in Type I diabetes. A control method for the automation of insulin infusion that utilizes emerging technologies in blood glucose biosensors is presented. The controller developed provides tighter, more optimal control of blood glucose levels, while accounting for variation in patient response, insulin employed an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Anaesthesia
سال: 1960
ISSN: 0003-2409,1365-2044
DOI: 10.1111/j.1365-2044.1960.tb13344.x