Drawing of magnesium fine wire and medical application of drawn wire

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Static Strain Aging Behavior of Low Carbon Steel Drawn Wire

The static strain aging is a phenomenon that can change the mechanical properties of low carbon steels. Thus, the static strain aging behavior of low carbon steel wires after drawing process is studied. To do so, the wires are austenitized at different temperatures and cooled in different rates. Then the wires are drawn and aged at a specific temperature and time. Before and after aging of each...

متن کامل

Developing Very Fine Nanopearlitic Structure in a High Carbon Steel Wire before Drawing

The effects of steel wire patenting process parameters on very fine interlamellar spacing in the pearlitic steel wire were investigated and the optimized condition of the process was achieved. In this work, the initial nanopearlitic structure was obtained in a 0.72 wt% carbon steel wire before the wire drawing process. The results were the minimum interlamellar spacing of 35 nm and maximum ulti...

متن کامل

Lawd – Laser Assisted Wire Drawing

In conventional wire drawing the diameter of a wire or rod-like workpiece is reduced by drawing it through a conical die. Dieless drawing of a wire or a rod is realized by a localized heating of the work piece. As heat source for example an induction coil can be used. Immediately after having passed the heating zone the work piece is cooled to restrict the heat input on very small region. By ap...

متن کامل

Investigation on cold-drawn gold bonding wire with serial and reverse-direction drawing

Gold bonding wires have been manufactured through multiple drawing steps with serial and reverse-direction drawing. The texture and microstrucure of the gold bonding wires were characterized with X-ray diffraction and EBSD and compared with the predictions of finite element (FE) imulation. Initial 〈1 0 0〉 fiber decreases during drawing and is replaced by 〈1 1 1〉 fiber. The 〈1 0 0〉 oriented grai...

متن کامل

Microstructure-sensitive Fatigue Modeling of Medical-grade Fine Wire

ACKNOWLEDGEMENTS This work would not have come to fruition were it not for the assistance and support I received from a great many people. I would like to express my thanks to my advisor, Dr. Richard Neu for providing direction throughout the research process, and for his expertise and helpful advice. I would also like to thank the members of my committee, Dr. David McDowell and Dr. Markus Reit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Procedia Manufacturing

سال: 2020

ISSN: 2351-9789

DOI: 10.1016/j.promfg.2020.08.050