Dual-echo Dixon imaging with flexible choice of echo times
نویسندگان
چکیده
منابع مشابه
Two-point Dixon imaging with flexible echo times and a region growing-based postprocessing algorithm
Introduction: The scan time for a two-point Dixon technique using dual-echo acquisition can become comparable with that for a conventional non-Dixon technique with similar scan parameters (1, 2). Recently, Xiang and Eggers et al. showed that images with echo times that are more flexible than being in-phase and out-of-phase can be used for two-point Dixon processing (3, 4). This increased flexib...
متن کاملDirect water and fat determination in two-point Dixon imaging with flexible echo times.
PURPOSE Identifying water and fat unambiguously in multipoint Dixon imaging often requires phase correction, which can be challenging and may fail. The purpose of this work is to present a geometric interpretation of the two-point Dixon method with flexible echo times (TEs) and to investigate the conditions under which water and fat can be determined directly without phase correction. METHODS...
متن کاملThree Echo Dixon Water-Fat Separation for Cardiac Black Blood Turbo Spin Echo Imaging
Introduction Turbo spin echo (TSE) sequences with black blood preparation pulses are an important component of cardiac MRI. It is commonly used for tissue characterization and anatomical assessment of the myocardium, e.g. for edema imaging aiming at the differentiation of acute from chronic myocardial infarction. TSE benefits from high SNR and the availability of good T1 or T2 weighting. So far...
متن کاملFast spin-echo triple-echo dixon (fTED) technique for efficient T2-weighted water and fat imaging.
Previously published fast spin-echo (FSE) implementations of a Dixon method for water and fat separation all require multiple scans and thus a relatively long scan time. Further, the minimum echo spacing (esp), a time critical for FSE image quality and scan efficiency, often needs to be increased in order to bring about the required phase shift between the water and fat signals. This work propo...
متن کاملIntensity-Corrected Dual-Echo Echo-Planar Imaging (DE-EPI) for Improved Pediatric Brain Diffusion Imaging
Here we investigate the utility of a dual-echo Echo-Planar Imaging (DE-EPI) Diffusion Weighted Imaging (DWI) approach to improve lesion conspicuity in pediatric imaging. This method delivers two 'echo images' for one diffusion-preparation period. We also demonstrate how the echoes can be utilized to remove transmit/receive coil-induced and static magnetic field intensity modulations on both ech...