Dual-pathway multi-echo sequence for simultaneous frequency and T2 mapping
نویسندگان
چکیده
منابع مشابه
Multi-Echo PRESTO: T2* mapping for 3D fMR1
Introduction Last year the Dual-Echo PRESTO [l] technique was introduced to measure I0 and T2* simultaneously. This technique is an extension of the PRESTO [2] technique (TE > TR) and allows for the acquisition of two echoes within each TR. The first echo with a short TE (-7 ms) is acquired directly after RF excitation and is immediately followed by an echo with a long TE (-43 ms) which is echo...
متن کاملSimultaneous Quantitative MRI Mapping of T1, T2* and Magnetic Susceptibility with Multi-Echo MP2RAGE
The knowledge of relaxation times is essential for understanding the biophysical mechanisms underlying contrast in magnetic resonance imaging. Quantitative experiments, while offering major advantages in terms of reproducibility, may benefit from simultaneous acquisitions. In this work, we demonstrate the possibility of simultaneously recording relaxation-time and susceptibility maps with a pro...
متن کاملSimultaneous T2 and T2* dynamic susceptibility contrast perfusion imaging using a multi-echo parallel imaging approach
Introduction. The utility of multi-echo DSC with gradient echo (GRE) EPI has recently been demonstrated for improved AIF determination, T1 independent contrast concentration estimation, and SNR recovery. In order to quantify the difference between the static and dynamic dephasing regimes, a gradient and spin echo (GRASE) multi-shot multi-echo EPI sequence is demonstrated. The hemodynamic parame...
متن کاملA technique for rapid single-echo spin-echo T2 mapping.
A rapid technique for mapping of T(2) relaxation times is presented. The method is based on the conventional single-echo spin echo approach but uses a much shorter pulse repetition time to accelerate data acquisition. The premise of the new method is the use of a constant difference between the echo time and pulse repetition time, which removes the conventional and restrictive requirement of pu...
متن کاملDual echo gradient echo imaging for simultaneous thermal mapping in cortical bone and soft tissue
Background/introduction MRI-guided high-intensity focused ultrasound (MRHIFU) therapy can relieve pain associated with metastatic and benign bone tumours in patients who fail to respond to conventional radiation therapy. However, since existing MR-thermometry techniques do not provide temperature information within the bone, HIFU exposures in bone are currently monitored using temperature chang...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Magnetic Resonance
سال: 2016
ISSN: 1090-7807
DOI: 10.1016/j.jmr.2016.01.019