Dual-rail optical gradient echo memory
نویسندگان
چکیده
منابع مشابه
Diffusion effects in gradient echo memory
X.-W. Luo,1,2 J. J. Hope,3 B. Hillman,3 and T. M. Stace1,* 1ARC Centre for Engineered Quantum Systems, University of Queensland, St Lucia, Queensland 4072, Australia 2Key Laboratory of Quantum Information, CAS, University of Science and Technology of China, Hefei, Anhui, 230026, People’sRepublic of China 3Department of Quantum Science, Research School of Physics and Engineering, Australian Nati...
متن کاملGradient echo memory in an ultra-high optical depth cold atomic ensemble
Quantum memories are an integral component of quantum repeaters—devices that will allow the extension of quantum key distribution to communication ranges beyond that permissible by passive transmission. A quantum memory for this application needs to be highly efficient and have coherence times approaching a millisecond. Here we report on work towards this goal, with the development of a 87Rb ma...
متن کاملDual Gradient-Echo Imaging of Ischemia/Reperfusion in Skeletal Muscle
B. M. Damon, J. L. Hornberger, J. A. Kent-Braun Radiology and Radiological Sciences, Vanderbilt University, Nashville, TN, United States, Institute of Imaging Science, Vanderbilt University, Nashville, TN, United States, Exercise Science, University of Massachusetts, Amherst, MA, United States Introduction Transient MRI signal intensity (SI) increases can be observed after brief isometric contr...
متن کاملDual Double-gradient-echo MRI for Liver Fat Content Analysis
We have devised a modified Dixon method for analyzing fatty infiltration of the liver using a dual doublegradient-echo (DDGRE) sequence. To correct the T2* decay, fourfold echo images were obtained by out-of-phase (TE = 2.3/6.9 ms) and in-phase (4.6/9.2 ms) double-echo sets during a single breath-hold scan on a 1.5 T MRI. The liver fat fractions obtained using the DDGRE method were determined i...
متن کاملGradient Echo
Principles and concepts of gradient echo (GRE) imaging are the basis of many applications on modern MR-systems. The most obvious difference between Spin Echo and GRE imaging is related to the pulse sequence elements that are used to generate an MR signal (see figure 1). While two rf-pulses (90 and 180) are used for spin refocusing and spin echo generation, GRE imaging is based on only a single ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Express
سال: 2015
ISSN: 1094-4087
DOI: 10.1364/oe.23.024937