Dynamic conformal arc cranial stereotactic radiosurgery: implications of multileaf collimator margin on dose–volume metrics

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic conformal arc cranial stereotactic radiosurgery: implications of multileaf collimator margin on dose-volume metrics.

OBJECTIVE The effect of multileaf collimator (MLC) margin on target and normal tissue dose-volume metrics for intracranial stereotactic radiosurgery (SRS) was assessed. METHODS 118 intracranial lesions of 83 SRS patients formed the basis of this study. For each planning target volume (PTV), five separate treatment plans were generated with MLC margins of -1, 0, 1, 2 and 3 mm, respectively. Id...

متن کامل

Comparison of volumetric‐modulated arc therapy and dynamic conformal arc treatment planning for cranial stereotactic radiosurgery

The aim was to analyze arc therapy techniques according to the number and position of the brain lesions reported by comparing dynamic noncoplanar conformal arcs (DCA), two coplanar full arcs (RAC) with volumetric-modulated arc therapy (VMAT), multiple noncoplanar partial arcs with VMAT (RANC), and two full arcs with VMAT and 10° table rotation (RAT). Patients with a single lesion (n= 10), multi...

متن کامل

Impact of the high-definition multileaf collimator on linear accelerator-based intracranial stereotactic radiosurgery.

OBJECTIVES The impact of two multileaf collimator (MLC) systems for linear accelerator-based intracranial stereotactic radiosurgery (SRS) was assessed. METHODS 68 lesions formed the basis of this study. 2.5 mm leaf width plans served as reference. Comparative plans, with identical planning parameters, were based on a 5 mm leaf width MLC system. Two collimation strategies, with collimation fix...

متن کامل

Dosimetric performance of the new high‐definition multileaf collimator for intracranial stereotactic radiosurgery

The objective was to evaluate the performance of a high-definition multileaf collimator (MLC) of 2.5 mm leaf width (MLC2.5) and compare to standard 5 mm leaf width MLC (MLC5) for the treatment of intracranial lesions using dynamic conformal arcs (DCA) technique with a dedicated radiosurgery linear accelerator. Simulated cases of spherical targets were created to study solely the effect of targe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The British Journal of Radiology

سال: 2012

ISSN: 0007-1285,1748-880X

DOI: 10.1259/bjr/79414773