Dynamic phase imaging of microscopic measurements using parallel interferograms generated from a cyclic shear interferometer
نویسندگان
چکیده
منابع مشابه
A Temporal Phase Unwrapping Algorithm Applied to Dynamic Interferograms Generated in Evaporating Picoliter Liquid Samples
Micromachined picoliter vials in silicon dioxide with a typical depth of 6μm are filled with a liquid sample. Epi-illuminated microscopic imaging during evaporation of the liquid shows dynamic fringe patterns. These fringe patterns are caused by interference between the direct part and the reflected part of an incident plane wave (reflected from the bottom of the vial). The optical path differe...
متن کاملX-ray phase contrast imaging using a grating interferometer
the differences in the absorption cross section of the constituents of the object. The technique yields excellent results where highly absorbing structures, e.g., bones, are embedded in a matrix of relatively weakly absorbing material, e.g., the surrounding tissue of the human body. However, in those cases where different forms of tissue with similar absorption crosssections are under investiga...
متن کاملAdvanced phase-contrast imaging using a grating interferometer.
Phase-sensitive X-ray imaging methods can provide substantially increased contrast over conventional absorption-based imaging, and therefore new and otherwise inaccessible information. Differential phase-contrast (DPC) imaging, which uses a grating interferometer and a phase-stepping technique, has been integrated into TOMCAT, a beamline dedicated to tomographic microscopy and coherent radiolog...
متن کاملPixelated Phase-Mask Dynamic Interferometer
We demonstrate a new type of spatial phase-shifting, dynamic interferometer that can acquire phase-shifted interferograms in a single camera frame. The interferometer is constructed with a pixelated phase-mask aligned to a detector array. The phase-mask encodes a high-frequency spatial interference pattern on two collinear and orthogonally polarized reference and test beams. The phase-differenc...
متن کاملPhase determination from mostly one-sided interferograms.
We show how to detect and correct for nonlinear phase shifts in a mainly one-sided interferogram of an emission-line source. We simultaneously detect and correct for an out-of-phase emission background from the spectrometer. The method requires two auxiliary spectra, one of a strong continuum source, and one of an emission-line source with little or no continuum.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Express
سال: 2014
ISSN: 1094-4087
DOI: 10.1364/oe.22.020185