Dynamic respiratory endoscopic findings pre- and post laryngoplasty in Thoroughbred racehorses

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic respiratory endoscopic findings pre- and post laryngoplasty in Thoroughbred racehorses.

REASONS FOR PERFORMING STUDY To investigate laryngeal function in cases of recurrent laryngeal neuropathy pre- and post laryngoplasty (LP) using dynamic respiratory endoscopy (DRE). OBJECTIVES To compare the rima glottidis area during DRE pre- and post LP; document all forms of dynamic upper airway obstruction (DUAO) pre- and post LP and investigate the relationship between post operative abd...

متن کامل

Dynamic upper respiratory abnormalities in Thoroughbred racehorses in South Africa.

Upper airway endoscopy at rest has been the diagnostic method of choice for equine upper respiratory tract (URT) conditions. Development of high-speed treadmill endoscopy improved the sensitivity of URT endoscopy by allowing observation of the horse's nasopharynx and larynx during exercise. However, treadmill exercise may not always accurately represent the horse's normal exercise as track surf...

متن کامل

Tracheal Endoscopic and Cytological Findings and Blood Examination Results in Thoroughbred Racehorses Suspected to have Lower Respiratory Tract Disease

Cytology of tracheal aspirates, tracheal endoscopic and blood tests were carried out to 86 Thoroughbred racehorses presenting coughs or poor performance which were suspected to have lower respiratory tract disease (LRTD) to assess the conditions of the disorders. Racehorses were classified into coughing (66 horses) and non-coughing (20 horses) groups based on clinical symptoms. Nine Thoroughbre...

متن کامل

Respiratory and cardiovascular adjustments during exercise of increasing intensity and during recovery in thoroughbred racehorses.

A new design of flowmeter is described and used in a comprehensive study of the respiratory and cardiovascular adjustments that occur during a standardised exercise test in Thoroughbred horses. The flowmeter system and associated lightweight, fibreglass mask (total mass, 0.7 kg) have a maximum dead space of 500 ml and negligible resistance to airflow. They have no systematic effect on blood gas...

متن کامل

48 - Veterinary aspects of training Thoroughbred racehorses

Thoroughbred racing evolved in England over 200 years ago and now exists in over 50 countries. A comparison of the size of Thoroughbred flat racing industries between some of the major racing countries based on foal crop, number of races and starters, prize money and betting turnover is illustrated in Table 48.1. All facets of the Thoroughbred racing industry rely heavily on veterinary input, w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Equine Veterinary Journal

سال: 2014

ISSN: 0425-1644

DOI: 10.1111/evj.12331