Dynamic response of a full-scale reinforced concrete building frame retrofitted with FRP column jackets

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Seismic Performance Analysis of FRP Reinforced Concrete Frame Structure

Based on the experimental study for seismic performance of FRP reinforced concrete beam-column joints, two-storey two-span plane frames were taken for examples, in which the static elastoplastic analysis (the pushover method) was carried on the joints of the FRP strengthened concrete frames, and then the comparative analysis was made on seismic performance of RFP strengthened frame structure th...

متن کامل

Full Scale Reinforced Concrete Beam-Column Joints Strengthened with Steel Reinforced Polymer Systems

This paper presents the results of an experimental campaign performed at the Laboratory of Materials and Structural Testing of the University of Salerno (Italy) in order to investigate the seismic performance of reinforced concrete (RC) beam-column joints strengthened with steel reinforced polymer (SRP) systems. With the aim to represent typical façade frames’ beam-column subassemblies found in...

متن کامل

Blast Design of Reinforced Concrete and Masonry Components Retrofitted with Frp

Fiber-reinforced polymer (FRP) products are used as an alternative to traditional methods for strengthening and retrofitting concrete and masonry structures to resist blast loads. The development and experimental validation of a methodology for modeling the response of blast loaded concrete and masonry structural components retrofitted with FRP, as well as corresponding response criteria, is im...

متن کامل

OPTIMUM RESISTANCE FACTOR FOR REINFORCED CONCRETE BEAMS RETROFITTED WITH U-WRAP FRP

The use of fiber reinforced polymer (FRP) U-wrap to rehabilitate concrete beams has increased in popularity over the past few years. As such, many design codes and guidelines have been developed to enable designers to use of FRP for retrofitting reinforced concrete beams. FIB is the only guideline for design which presents a formula for torsional capacity of concrete beams streng...

متن کامل

Microwave Cylindrical Reflection Tomography Array for Damage Detection in Civil Structures

The enhanced structural performance of Reinforced Concrete (RC) columns retrofitted by Fiber Reinforced Polymer (FRP) composite jackets, has been well demonstrated and an increasingly large number of bridge and building columns have been retrofitted with such jackets in the United States and elsewhere. However, seismic damage such as debonding between the jacket and the column that can consider...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Engineering Structures

سال: 2016

ISSN: 0141-0296

DOI: 10.1016/j.engstruct.2016.07.016