Dynamic response of a full-scale reinforced concrete building frame retrofitted with FRP column jackets
نویسندگان
چکیده
منابع مشابه
Seismic Performance Analysis of FRP Reinforced Concrete Frame Structure
Based on the experimental study for seismic performance of FRP reinforced concrete beam-column joints, two-storey two-span plane frames were taken for examples, in which the static elastoplastic analysis (the pushover method) was carried on the joints of the FRP strengthened concrete frames, and then the comparative analysis was made on seismic performance of RFP strengthened frame structure th...
متن کاملFull Scale Reinforced Concrete Beam-Column Joints Strengthened with Steel Reinforced Polymer Systems
This paper presents the results of an experimental campaign performed at the Laboratory of Materials and Structural Testing of the University of Salerno (Italy) in order to investigate the seismic performance of reinforced concrete (RC) beam-column joints strengthened with steel reinforced polymer (SRP) systems. With the aim to represent typical façade frames’ beam-column subassemblies found in...
متن کاملBlast Design of Reinforced Concrete and Masonry Components Retrofitted with Frp
Fiber-reinforced polymer (FRP) products are used as an alternative to traditional methods for strengthening and retrofitting concrete and masonry structures to resist blast loads. The development and experimental validation of a methodology for modeling the response of blast loaded concrete and masonry structural components retrofitted with FRP, as well as corresponding response criteria, is im...
متن کاملOPTIMUM RESISTANCE FACTOR FOR REINFORCED CONCRETE BEAMS RETROFITTED WITH U-WRAP FRP
The use of fiber reinforced polymer (FRP) U-wrap to rehabilitate concrete beams has increased in popularity over the past few years. As such, many design codes and guidelines have been developed to enable designers to use of FRP for retrofitting reinforced concrete beams. FIB is the only guideline for design which presents a formula for torsional capacity of concrete beams streng...
متن کاملMicrowave Cylindrical Reflection Tomography Array for Damage Detection in Civil Structures
The enhanced structural performance of Reinforced Concrete (RC) columns retrofitted by Fiber Reinforced Polymer (FRP) composite jackets, has been well demonstrated and an increasingly large number of bridge and building columns have been retrofitted with such jackets in the United States and elsewhere. However, seismic damage such as debonding between the jacket and the column that can consider...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Engineering Structures
سال: 2016
ISSN: 0141-0296
DOI: 10.1016/j.engstruct.2016.07.016