Dynamic Simulation of Variable-Speed Valve-Controlled-Motor Drive System with a Power-Assisted Device

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Difference between Slip Ring Motor with Conventional Drive and Squirrel Cage Motor with Variable Speed Drive

This paper shows a comparison simulation results for two controllers using the same name plate of 2750 KW, 6.6 KV, 50 HZ for wound and squirrel cage motors using two methods of controlling, the first method is achieved by a conventional method and the second method is achieved by a frequency inverter respectively. Keywords— Squirrel cage and slip ring motors, conventional and VSD controllers si...

متن کامل

Modern Topology& Thermal Analysis of Drive for Variable Speed Pumped Storage Power Plant

Given the significant power generation and consumption of variable-speed pumped storage power plants (VSPSPs), it is crucial to enhance drive methods and decrease drive losses, thereby increasing productivity. This paper proposes the topology for VSPSP drivers with two level voltage source converters (2LVSC) with 6+1 converters. Hydraulic and electrical VSPSP models are presented, following whi...

متن کامل

Real Time Dynamic Simulation of Power System Using Multiple Microcomputers

Recent developments in the design and manufacture of microcomputers together with improved simulation techniques make it possible to achieve the speed and accuracy required for the dynamic simulation of power systems in real time. This paper presents some experimental results and outlines new ideas on hardware architecture, mathematical algorithms and software development for this purpose. The ...

متن کامل

Modeling and Simulation of a Novel Switched Reluctance Motor Drive System with Power Factor Improvement

This study presents a novel Switched Reluctance Motor (SRM) drive system with power factor improvement. Recently, many of the converters with variable speed drives have no input power factor correction circuits. This results in harmonic pollution of the utility supply, which should be avoided. The effect of power factor variation in terms of harmonic content is also analyzed in this study. The ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Strojniški vestnik – Journal of Mechanical Engineering

سال: 2014

ISSN: 0039-2480

DOI: 10.5545/sv-jme.2013.1532