Early Clinical Experience with Cloth-Covered Valvular Prostheses
نویسندگان
چکیده
منابع مشابه
Cloth destruction and haemolysis with totally cloth-covered Starr-Edwards prostheses.
Four cases are described in which totally cloth-covered Starr-Edwards valves (model 2300) had to be removed. All were causing significant haemolysis, two in the absence of a peripheral leak. The principal operative finding was destruction of the Dacron covering the struts. Following replacement of these prostheses there was complete resolution of signs and symptoms. The possible causes of haemo...
متن کاملResults after mitral valve replacement with cloth-covered Starr-Edwards prostheses (models 6300, 6310/6320, and 6400).
The actuarial survival and thromboembolic rates for the three types of cloth-covered Starr-Edwards mitral prostheses, models 6300, 6310/6320, and 6400 followed 6, 5, and 2 years, respectively, were not significantly different throughout the years they were followed. The combined cumulative survival and thromboembolic proportion at 5 years for these prostheses were 71 and 66 per cent, respective...
متن کاملThrombo-embolic complications of the cloth-covered Starr-Edwards prostheses No. 2300 aortic and No. 6300 mitral.
The thrombo-embolic complications of the cloth-covered Starr-Edwards prostheses No. 2300 aortic and No. 6300 mitral followed for an average of 14 months in 155 patients are reviewed. There was a high incidence of early fatal and disabling thrombo-embolus in patients 'having mitral valve replacement. Late emboli were more common after aortic valve replacement. Anticoagulant control was unsatisfa...
متن کاملImaging of Metallic Prostheses Using Novel Sequences: Early Experience
For many years, diagnostic imaging in patients with metallic implants had been limited to plain X-rays and nuclear medicine studies. Although there have been advancements with regards to imaging of hardware using computed tomography, many of the changes involve increasing the radiation dose at a time when the public has become increasingly sensitive to reported long term risk of carcinogenesis ...
متن کاملValve dysfunction of the cloth-covered Starr-Edwards ball valve.
BACKGROUND Between June 1968 and March 1977, Starr-Edwards cloth-covered ball valves were used for valve replacement on a routine basis. METHODS AND RESULTS Among the 66 operative survivors who underwent an isolated aortic or mitral valve replacement, 20 patients required reoperation 22 times because of valve dysfunction, thromboembolic complication, paravalvular leakage, hemolytic anemia, an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Annals of Surgery
سال: 1969
ISSN: 0003-4932
DOI: 10.1097/00000658-196909010-00015