Early Clinical Experience with Varian Halcyon V2 Linear Accelerator: Dual -Isocenter IMRT Planning and Delivery with Portal Dosimetry for Gynecological Cancer Treatments
نویسندگان
چکیده
منابع مشابه
Commissioning and early experience with a new generation low-energy linear accelerator in zahedan
Introduction: Since commissioning beam data are treated as a reference and ultimately used by treatment planning systems, it is vitally important that the collected data are of the highest quality to avoid dosimetric and patient treatment errors that may subsequently lead to a poor radiation outcome. Beam data commissioning should be performed with appropriate knowledge and pr...
متن کاملPractical approach for pretreatment verification of IMRT with flattening filter‐free (FFF) beams using Varian portal dosimetry
Patient-specific pretreatment verification of intensity-modulated radiation therapy (IMRT) or volumetric-modulated arc therapy (VMAT) is strongly recommended for all patients in order to detect any potential errors in treatment planning process and machine deliverability, and is thus performed routinely in many clinics. Portal dosimetry is an effective method for this purpose because of its pro...
متن کاملClinical experience of the importance of daily portal imaging for head and neck IMRT treatments
The purpose of this study was to evaluate patient setup in head and neck IMRT using daily portal imaging. At our institution, orthogonal digital portal images are taken daily to check patient positioning prior to head and neck IMRT treatment. Isocenter misalignments are corrected using a couch shift (3mm action level). Therapists also compare the DRRs and portal images looking at points more di...
متن کاملQuality Assurance of IMRT delivery systems – Varian
Introduction Intensity modulated radiation therapy (IMRT) provides the means for improved treatment for a wide variety of cancers. Piggybacked onto 3DCRT and MLC technologies, IMRT has developed quickly, but will undoubtedly see improvements in core hardware and software as well as in peripheral applications such as record and verify, gating, etc. At the core, individual treatment centers shoul...
متن کاملClinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification.
The aim of this study was to demonstrate how dosimetry with an amorphous silicon electronic portal imaging device (a-Si EPID) replaced film and ionization chamber measurements for routine pre-treatment dosimetry in our clinic. Furthermore, we described how EPID dosimetry was used to solve a clinical problem. IMRT prostate plans were delivered to a homogeneous slab phantom. EPID transit images w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Radiation Oncology*Biology*Physics
سال: 2019
ISSN: 0360-3016
DOI: 10.1016/j.ijrobp.2019.06.962