Early Perceval Valve Thrombosis
نویسندگان
چکیده
We report a case of early thrombosis sutureless Perceval valve after aortic replacement (AVR). Previous reports described AV between 1-12 months [1, 2]. However, the patient was diagnosed with dysfunction 3 days later.
منابع مشابه
Perceval Sutureless Valve – are Sutureless Valves Here?
With the advent of transcatheter aortic valve implantation (TAVI) techniques, a renewed interest has developed in sutureless aortic valve concepts in the last decade. The main feature of sutureless aortic valve implantation is the speed of insertion, thus making implantation easier for the surgeon. As a result, cross clamp times and myocardial ischemia may be reduced. The combined procedures (C...
متن کاملVery Early Thrombosis of Sapien 3 Valve.
A 74-year-old man at moderate risk for surgical aortic valve replacement underwent transcatheter aortic valve replacement (TAVR) with an Edwards S3 valve (Edwards Lifesciences, Irvine, California) via the transfemoral route. Past medical history was significant for coronary artery bypass graft surgery. Left ventricular ejection function was normal, and he was in sinus rhythm. A 26-mm valve was ...
متن کاملEarly Clinical Results of Perceval Sutureless Aortic Valve in 139 Patients: Freeman Experience
OBJECTIVE The aim of this retrospective study is to evaluate the safety and performance of the Perceval sutureless valve in patients undergoing aortic valve replacement. We report the 30-day clinical outcomes of 139 patients. METHODS From January 2014 to December 2016, 139 patients underwent sutureless aortic valve replacement. Their operation notes, National Adult Cardiac Surgery Database an...
متن کاملMinimally invasive aortic valve replacement using the Perceval S sutureless valve.
The term “sutureless aortic valve” (su-AV) describes a type of valve which facilitates anchoring of bioprostheses in the aortic position without use of conventional sutures. Although all valve prostheses used for transcatheter aortic valve implantation or replacement (TAVI or TAVR) follow the same principle, they are implanted by wire-based techniques as opposed to su-AVs, which are implanted b...
متن کاملEarly transcatheter heart valve thrombosis detected by multidetector computed tomography
Article history: Received 7 November 2013 Accepted 18 November 2013 Available online 27 November 2013 IA–IC in the online-only Data Supplement). No paravalvular or central leakage was detected and LVEF was unaltered. Echocardiographic image quality did not allow for adequate assessment with regard to the mechanism of THV dysfunction. Contrast-enhanced multidetector computed tomography (MDCT) wa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Surgery Case Reports
سال: 2022
ISSN: ['2733-225X']
DOI: https://doi.org/10.31487/j.jscr.2022.01.04