Editorial of the Special Issue “Seismic Vulnerability and Strengthening of Unreinforced Masonry Buildings”

نویسندگان

چکیده

Historical structures represent a significant percentage of existing constructions in numerous seismic-prone regions, and some these are iconic monuments their countries [...]

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simplified indexes for the seismic vulnerability of ancient masonry buildings

This paper presents a contribution for the safety assessment of historical masonry buildings under seismic loading. Three different simplified safety indexes (in-plan area ratio, area to weight ratio and base shear ratio) are analyzed, taking into account a large sample of fifty-eight Portuguese churches. The sample of building has been organized according to the seismic zonation, from high to ...

متن کامل

Seismic Design of Box-Type Unreinforced Masonry Buildings Through Direct Displacement-Based Approach

In the last decade, displacement-based seismic design procedures have been recognised to be effective alternatives to force-based design (FBD) methods. Indeed, displacement based design (DBD) may allow the structural engineer to get more realistic predictions of local and global deformations of the structure, and hence damage, under design earthquakes. This facilitates the achievement of perfor...

متن کامل

Towards Displacement-Based Seismic Design of Modern Unreinforced Masonry Structures

Unreinforced masonry (URM) structures are known to be rather vulnerable to seismic loading. Modern URM buildings with reinforced concrete (RC) slabs might, however, have an acceptable seismic performance for regions of low to moderate seismicity. In particular in countries of moderate seismicity it is often difficult to demonstrate the seismic safety of modern URM buildings by means of force-ba...

متن کامل

Damage Accumulation in Unreinforced Masonry Due to Seismic Loading

Masonry has low cohesive strength and is susceptible to the brittle failure, when subjected to induced tensile stresses. It fails due to lateral tensile stresses even when masonry prisms are tested in uni-axial static compression and the stress-strain curve remains almost linear up to failure. Although masonry normally resists compressive forces, under lateral in-plane cyclic loads some parts o...

متن کامل

Editorial for Special Issue of Microbiota

Editorial for Special Issue of Microbiota Bagher Larijani Professor, Endocrinology and Metabolism Research Center, Endocrinology and Metabolism Clinical Sciences Institute, Tehran University of Medical Sciences, Tehran, Iran

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Geosciences

سال: 2023

ISSN: ['2076-3263']

DOI: https://doi.org/10.3390/geosciences13030062