Effect of evaporator temperature on vapor compression refrigeration system

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mathematical Model of a Complete Vapor Compression Refrigeration System with Helical Coil Evaporator Flooded in the Water

Refrigeration cycle system modelling of the vapor compression experimental unit with the goal to predict the system performance of the cycle and geometry of the helical coil evaporator flooded in the water is presented in the paper. Design of the experimental unit is based on the commercially available scroll compressor and air cooled condenser. In order to determine the thermodynamic condition...

متن کامل

Modeling And Validation Of A Multi-Evaporator Vapor Compression Cycle Subject To Non-Uniform Loading In Transport Refrigeration Applications

This paper describes a multi-evaporator vapor compression model capable of simulating the dynamic behaviour of transport refrigeration systems. A discrete multi-zone control volume approach is utilised for modelling the condenser and evaporators. All other major refrigeration components including compressor, expansion valves, receiver, pressure-regulating valves are modeled using time-dependent...

متن کامل

Cooling Capacity Control for Multi-Evaporator Vapor Compression Systems

Multi-evaporator vapor compression systems (ME-VCS) provide cooling to multiple zones. The thermodynamic conditions in these zones are independent: the heat loads often differ, and the occupants of these spaces often have different desired room temperatures. Therefore, in order to regulate each zone to its desired setpoint temperature, the amount of thermal energy removed by each evaporator mus...

متن کامل

Dynamical modeling and thermo-economic optimization of a cold room assisted vapor-compression refrigeration cycle

A cold room assisted vapor-compression refrigeration cycle is dynamically modeled in a year and optimized. Total annual cost (TACO) and coefficient of performance (COP) are selected as two objective functions. Both cold room and refrigeration cycle parameters are considered as design variables. Moreover, three working fluids included R22, R134a and R407c are examined. The optimum Pareto front r...

متن کامل

Using Carbon Dioxide in a Transcritical Vapor Compression Refrigeration Cycle

For most of the last fifty years, refrigeration and heat pump systems have been based on cycles using a fluorocarbon as the working fluid. Hovvever, with the discovery that fluorocarbons may have a profoundly detrimental effect on the earth ·s atmosphere. it has become necessary to find a suitable replacement for a fluorocarbon based refrigeration cycle. Such a replacement must perform comparab...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Alexandria Engineering Journal

سال: 2011

ISSN: 1110-0168

DOI: 10.1016/j.aej.2010.08.003