Effect of Plate Wettability on Dispersed-Phase Holdup in a Pulsed Disc-and-Doughnut Solvent Extraction Column

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prediction of Dispersed Phase Holdup in the Kühni Extraction Column Using a New Experimental Correlation and Artificial Neural Network

In this work, the dispersed phase holdup in a Kühni extraction column is predicted using intelligent methods and a new empirical correlation. Intelligent techniques, including multilayer perceptron and radial basis functions network are used in the prediction of the dispersed phase holdup. To design the network structure and train and test the networks, 174 sets of experimental data are used. T...

متن کامل

Prediction of Dispersed Phase Holdup in Scheibel Extraction Columns by a New Correlation

In this study, the effect of operating parameters on dispersed phase holdup in liquid-liquid extraction process has been investigated. Three chemical systems (Toluene/Water, Butyl acetate/Water, and n-Butanol/Water) were utilized and holdup was considered in a wide range of interfacial tensions through a Scheibel extraction column. Various rotor speeds were examined on the certain velocities of...

متن کامل

Mass Transfer Coefficients in Pulsed Column for Separation of Samarium and Gadolinium

The mass transfer performance of a pulsed disc and doughnut column for extraction of samarium and gadolinium from aqueous nitrate solution with D2EHPA was investigated. The effects of operating parameters such as pulsation intensity, continuous and dispersed phase velocities on column performance were investigated. The axial dispersion model was used to obtain the overall mass transfer coef...

متن کامل

بررسی تجربی تغییرات انباشت فاز پراکنده با ارتفاع در ستونهای استخراج مایع- مایع ضربه‌ای سینی دار

Holdup was measured at various frequencies, amplitudes, continuous and dispersed phase flow rates for binary systems in a pulsed plate column capable of providing samples at various heights. The binary systems was so selected as to cover a wide spectrum of interfacial tensions. Dispersed phase holdup was found to increase with height in a logarithmic fashion at conditions away from the flooding...

متن کامل

Dispersion Parameters and Effect of Impeller Speed, Holdup and Volume Fraction of Dispersed Phase on Separation Efficiency, Mass Transfer Coefficient of Dispersed Phase and Distribution Coefficient on Mixer-Settler Set

An experimental study has been conducted on the hydrodynamics of a stage mixer-settler to obtain an appropriate design. In this paper several tests was performed to investigate full factorial design of experiments. Since each test was repeated seven times, the repeatability of the test was confirmed (P=1 bar and T=25 °C). Sauter diameter was determined by photographing both the mix...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Solvent Extraction and Ion Exchange

سال: 2017

ISSN: 0736-6299,1532-2262

DOI: 10.1080/07366299.2017.1399570