Effect of Regional Tracer Delay on CBF in Healthy Subjects Measured with Dynamic Susceptibility Contrast-Enhanced MRI: Comparison with 15O-PET

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of regional tracer delay on CBF in healthy subjects measured with dynamic susceptibility contrast-enhanced MRI: comparison with 15O-PET.

PURPOSE Deconvolution based on truncated singular value decomposition (SVD deconvolution) is a promising method for measuring cerebral blood flow (CBF) with dynamic susceptibility contrast-enhanced magnetic resonance imaging (DSC-MRI), but it has proved extremely sensitive to tracer delay. The purpose of this study was to investigate the effect of regional tracer delay on CBF determined by SVD ...

متن کامل

Tracer delay correction of cerebral blood flow with dynamic susceptibility contrast-enhanced MRI.

Cerebral blood flow (CBF) and vascular mean transit time (MTT) can be determined by dynamic susceptibility contrast-enhanced magnetic resonance imaging and deconvolution with an arterial input function. However, deconvolution by a singular value decomposition (SVD) method is sensitive to the tracer delay that often occurs in patients with cerebrovascular disease. We investigated the effect of t...

متن کامل

Noninvasive Evaluation of CBF and Perfusion Delay of Moyamoya Disease Using Arterial Spin-Labeling MRI with Multiple Postlabeling Delays: Comparison with 15O-Gas PET and DSC-MRI.

BACKGROUND AND PURPOSE Arterial spin-labeling MR imaging with multiple postlabeling delays has a potential to evaluate various hemodynamic parameters. To clarify whether arterial spin-labeling MR imaging can identify CBF and perfusion delay in patients with Moyamoya disease, we compared arterial spin-labeling, DSC, and 15O-gas PET in terms of their ability to identify these parameters. MATERI...

متن کامل

Dynamic susceptibility contrast perfusion MRI (with pitfalls)

Since the first studies in the late 1980s and early 1990s, dynamic susceptibility contrast MRI (DSC-MRI, also known as ‘bolus tracking’) has become a very powerful technique for the assessment of perfusion, and perfusion-related parameters (see (1,2) for recent reviews). Despite the need of an exogenous MR agent (cf. arterial spin labeling techniques), DSC-MRI is currently the most common MR pe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Magnetic Resonance in Medical Sciences

سال: 2005

ISSN: 1347-3182,1880-2206

DOI: 10.2463/mrms.4.27