EFFECT OF VARIABLE PHACO TIMES OF CONSTANT PHACO POWER ON MACULAR THICKNESS
نویسندگان
چکیده
Background: Various factors involved in phaco can influence the tissue structures of eyeball Ultrasonic energy should be taken into consideration as a risk factor that may affect structure eyeball. Objective: To evaluate changes on macular thickness before and after phacoemulsification surgery with variable Phaco Times constant power by Optical Coherence Tomography (OCT). Patients methods: A prospective observational clinical study 40 eyes Nuclear cataract grade II-III. All patients under went full medical ophthalmic history, history ocular surgeries, complete examination include ingvisual acuity: Uncorrected VA (UCVA) best corrected (BCVA),Anterior segment using Slit-lamp bio microscopy, Intraocular pressure (IOP) measurement applanation tonometry, Fundus examination, OCT was done preoperatively then 4-6 weeks postoperatively. Results: In cataract, there no significant correlation between postoperative (MT) time. Conclusion: After times power, time.
منابع مشابه
Comparison between phaco-deep sclerectomy converted into phaco-trabeculectomy and uneventful phaco-deep sclerectomy.
PURPOSE To evaluate and compare the results and complications of eyes that underwent a phaco-deep sclerectomy (DS) converted into phaco-trabeculectomy due to an intraoperative macroperforation with eyes undergoing uneventful phaco-DS. METHODS The authors reviewed 106 eyes having a planned phaco-DS; 10 of them (9.4%) had to be converted into phaco-trabeculectomy because of a large perforation ...
متن کاملCataraCt Surgery PhaCo PearlS
june 2013 CataraCt & refraCtive Surgery today 19 AlAn S. CrAndAll, Md I would plan on using iris hooks to keep the iris from interfering with phacoemulsification, so I would create two extra paracenteses. If the astigmatism were regular, I would implant a toric IOL. If the astigmatism were irregular, I would not address it initially. Given the amount of trauma to the eye, my primary concern wou...
متن کاملComparison of divide and conquer and phaco-chop techniques during fluid-based phaco-emulsification.
PURPOSE To determine whether, similar to ultrasound phaco-emulsification, applied energy and surgery time decrease using phaco-chop nucleus fragmentation method compared to divide and conquer technique using the fluid-based system. METHODS This prospective, comparative, randomized clinical study included patients with cataract who were randomly assigned to use either standard divide and conqu...
متن کاملeffect of oral presentation on development of l2 learners grammar
this experimental study has been conducted to test the effect of oral presentation on the development of l2 learners grammar. but this oral presentation is not merely a deductive instruction of grammatical points, in this presentation two hypotheses of krashen (input and low filter hypotheses), stevicks viewpoints on grammar explanation and correction and widdowsons opinion on limited use of l1...
15 صفحه اولPhaco Chop: Pearls and Pitfalls
Since Kunihiro Nagahara’s original presentation at the 1993 ASCRS meeting, several different variations of chopping have evolved. Conceptually these can be divided into two main categories. I call the classic Nagahara technique horizontal chopping, because the instrument tips move toward each other in the horizontal plane during the chop. In vertical chopping, the two instrument tips move towar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Al-Azhar Medical Journal
سال: 2021
ISSN: ['1110-0400']
DOI: https://doi.org/10.21608/amj.2021.139740